AWWA-D100 AWWA Standard for Welded Carbon Steel Tanks for Water Storage

AWWA-D100 - 2021 EDITION - CURRENT
Show Complete Document History


AWWA Standard for Welded Carbon Steel Tanks for Water Storage

Scope

The purpose of this standard is to provide guidance to facilitate the design, manufacture, and procurement of welded carbon steel tanks for the storage of water. This standard does not cover all details of design and construction because of the large variety of sizes and shapes of tanks.

Where details for any specific design are not given, it is intended that the constructor, subject to the approval of the purchaser, shall provide details that are designed and constructed to be adequate and as safe as those that would otherwise be provided under this standard.

ANSI/AWWA D100-11 does not cover all details of design and construction because of the large variety of sizes and shapes of tanks. Details that are not addressed shall be designed and constructed to be adequate and as safe as those that would otherwise be provided under this standard. And this standard does not cover concrete–steel composite tank construction.

  

Notes

Claudia's Notes:
This edition of the standard includes numerous corrections, updates, and new material to clarify some of the existing requirements.

1. Section 1 was revised to show the latest edition of references.

2. Section 3 was revised to match the wind exposure definitions of ASCE 7-05. The requirement that dome roofs constructed of aluminum shall comply with ANSI/AWWA D108 was added. The stress evaluation procedure of ASME SECTION VIII, DIV. 2 was added as an acceptable method for evaluating local shell or pedestal stress for anchor chair designs that are based on a detailed analysis.

3. Section 10 was revised to include an erection tolerance multiplier for elements of ground-supported flat-bottom tanks that are designed in accordance with Sec. 3.4.4 and subject to small compressive stresses.

4. Section 11 was revised to make leak testing of the bottom-to-shell joint mandatory for all ground-supported flat-bottom tanks.

5. Section 13 was revised to not require a site response analysis for short-period structure located on liquefiable soils. The site-specific procedure of FEMA 450 was deleted, and the site-specific procedures of ASCE 7-05 were referenced. The scaling requirement for the alternate procedures was clarified.

6. Section 14 was revised to clarify the DMT-thickness requirement for Category 1 and Category 2 materials when impacts are provided.

7. Section 15, covering dome roofs constructed of aluminum, was deleted and replaced with a reference to ANSI/AWWA D108.


This document comes with our free Notification Service, good for the life of the document.

This document is available in Paper format.

 

Customers who bought this document also bought:

API-620
Design and Construction of Large, Welded, Low-Pressure Storage Tanks

MIL-C-26482
Connectors, Electrical, (Circular, Miniature, Quick Disconnect, Environment Resisting)

ASME-HST-5
Performance Standard for Air Chain Hoists

ORDER

Price:

$195.75




Document Number

AWWA D100-21

Revision Level

2021 EDITION

Status

Current

Publication Date

Dec. 1, 2021