ASTM-C1714 › Historical Revision Information
Standard Specification for Preblended Dry Mortar Mix for Unit Masonry
The following bibliographic material is provided to assist you with your purchasing decision:
This specification covers unit masonry mortars whose material and design requirements are governed by a referenced ASTM document stated herein, but are preblended dry in a factory instead of produced from individual raw materials delivered to the job-site. Because field sampling, testing, directly comparable test results, packaging, and traceability of ingredients of preblended dry mortar mix differ from job site mixed mortars, this specification particularly addresses these issues, along with the tight control of ingredient ratios possible with preblended dry mortars.
Scope
1.1 This specification covers masonry mortars whose materials and design requirements are governed by Specification C270 but are preblended dry in a factory instead of produced from individual raw materials delivered to the job-site.
1.2 The field-sampling, testing, directly comparable test results, packaging, and the traceability of ingredients of preblended dry mortar mix differ from job site mixed mortars and this standard specifically addresses these issues. The tight control of ingredient ratios possible with preblended dry mortar is also covered.
1.3 The text of this specification refers to notes and footnotes, which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered the requirements of the standard.
1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.
Keywords
additive; admixture; batch number; dry mortar; masonry; masonry cement; mortar; mortar cement; mortar materials; packaged; portland cement and lime; preblended; preblended dry mixed mortar; ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
To find similar documents by ASTM Volume:
To find similar documents by classification:
91.100.10 (Cement. Gypsum. Lime. Mortar)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ASTM-C1714/C1714M-09
Revision Level
2009 EDITION
Status
Superseded
Modification Type
New
Publication Date
Dec. 15, 2009
Document Type
Specification
Page Count
4 pages
Committee Number
C12.03