ASTM-D4591 Historical Revision Information
Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry

ASTM-D4591 - 2007 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Determining Temperatures and Heats of Transitions of Fluoropolymers by Differential Scanning Calorimetry
ORDER

Scope

1.1 This test method defines conditions for the use of differential scanning calorimetry (DSC) with fluoropolymers. It covers the use of DSC analyses with the fluoropolymers, PTFE, PVDF, PCTFE, and PVF and their copolymers PFA, MFA, FEP, ECTFE, EFEP, VDF/HFP, VDF/TFE/HFP, VDF/CTFE. The test method is applicable to the analysis of powders as well as samples taken from semi-finished or finished products. The nature of fluoropolymers is such that special procedures are needed for running DSC analysis and interpreting the results.

1.2 The values stated in SI units as detailed in IEEE/ASTM SI-10 are to be regarded as the standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

There is currently no ISO standard that duplicates this test method. ISO 12086-1 and ISO 12086-2 cover similar testing and reference this test method for testing conditions.

Significance and Use

DSC analysis may be used with fluoropolymers to achieve at least four different objectives as follows:

4.1.1 To measure transition temperatures to aid in the identification of the various fluoropolymers, individually or in mixtures;

4.1.2 To compare the relative levels of crystalline content of two or more specimens of a sample of a fluoropolymer relative to another sample by measuring the heat of fusion;

Note 2—Absolute values of crystalline content cannot be determined until values for heats of fusion of the completely crystalline polymers are available.

4.1.3 To characterize PTFE (DSC thermal curves determined on powders or products of PTFE that have never been melted convey appreciable information about details of morphology and molecular structure);4

4.1.4 To supplement the test for standard specific gravity (SSG) described in Specifications D 4894 and D 4895 by using the heat of crystallization of pure PTFE homopolymer, depending on the relative molecular weight of the specimen. The scopes of these specifications, however, include PTFE resins modified with small amounts of comonomers, and many commercial PTFE resins are modified in this manner. These modifications can have profound effects on crystallization behavior. Published relationships4 between heat of crystallization and molecular weight refer to pure PTFE homopolymers and, therefore, cannot be applied to the modified resins.

Keywords

differential scanning calorimetry; DSC; fluoropolymer(s); heats of fusion; melting point; thermal analysis; ICS Number Code 83.080.20 (Thermoplastic materials)

To find similar documents by ASTM Volume:

08.02 (Plastics (II): D3222 - D5083)

08.03 (Plastics (III): D5117 - latest; Reinforced Plastic Piping Systems and Chemical Equipment; Plastic Building Products)

To find similar documents by classification:

83.080.20 (Thermoplastic materials)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D4591-07

Revision Level

2007 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

March 1, 2007

Document Type

Test Method

Page Count

4 pages

Committee Number

D20.15