ASTM-D5907 Historical Revision Information
Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable Matter (Total Suspended Solids) in Water

ASTM-D5907 - 2010 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable Matter (Total Suspended Solids) in Water
ORDER

Scope

1.1 These test methods cover the determination of filterable matter, total dissolved solids (TDS), and nonfilterable matter, total suspended solids (TSS), in drinking, surface, and saline waters, domestic and industrial wastes. The practical range of the determination of nonfilterable particulate matter (TSS) is 4 to 20 000 mg/L. The practical range of the determination of filterable matter (TDS) is 10 mg/L to 150 000 µg/g.

1.2 Since the results measured by this test are operationally defined, careful attention must be paid to following the procedure as specified.

1.3 The test methods appear in the following order:

Filterable Matter (TDS) and
Nonfilterable Matter (TSS), mg/L
Sections 10-14
Total Dissolved Solids
High Precision Method, µg/g
Sections 15-19

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For a specific hazard statement, see Section 8.

Significance and Use

Solids, both as filterable matter (TDS) and nonfilterable matter (TSS), are important in the treating of raw water and wastewater, and in monitoring of streams.

Waste solids impose a suspended and settleable residue in receiving waters. Suspended and soluble materials provide a matrix for some biological slime and, in sufficient quantity, impair respiration of organisms. These solids may create nuisance slime beds and odors while imposing a long-term biological oxidation load over limited receiving water areas.

Knowledge of suspended and soluble materials is important in treating raw water supplies. Knowledge of solids loading can aid in determining the type or amount of treatment, or both, necessary to make the water acceptable for use. Such information may also be used to determine acceptability of water after treatment. Too little treatment may not be desirable and excess treatment costs money.

Stream monitoring is important for environmental reasons, such as compliance with discharge permits. Stream improvements, water pollution monitoring, mass wasting, algal studies, and sediment loads are but a few of the many reasons streams are monitored.

Keywords

dissolved matter; filterable matter; nonfilterable matter; suspended matter; total dissolved solids; total suspended solids; Dissolved elements (of water); Drinking water; Filters/filter procedures--water testing; Industrial water treatment; Nonfilterable matter; Surface water; Suspended matter; Trace elements--water analysis; ICS Number Code 13.060.60 (Examination of water for physical properties)

To find similar documents by ASTM Volume:

11.01 (Water (I))

To find similar documents by classification:

13.060.60 (Examination of physical properties of water)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D5907-10

Revision Level

2010 EDITION

Status

Superseded

Modification Type

Revision with Title Change

Publication Date

Oct. 1, 2010

Document Type

Test Method

Page Count

9 pages

Committee Number

D19.05