ASTM-D6450 Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester

ASTM-D6450 - 2016A R21 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Flash Point by Continuously Closed Cup (CCCFP) Tester
ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This flash point test method is a dynamic method and depends on definite rates of temperature increase. It is one of the many flash point test methods available, and every flash point test method, including this one, is an empirical method.

Note 1- Flash point values are not a constant physical-chemical property of materials tested. They are a function of the apparatus design, the condition of the apparatus used, and the operational procedure carried out. Flash point can therefore only be defined in terms of a standard test method, and no general valid correlation can be guaranteed between results obtained by different test methods or with test appartus different from that specified.

1.2 This test method covers the determination of the flash point of fuel oils, lube oils, solvents, and other liquids by a continuously closed cup tester. The measurement is made on a test specimen of 1 mL.

1.3 This test method utilizes a closed but unsealed cup with air injected into the test chamber.

1.4 This test method is suitable for testing samples with a flash point from 10 to 250°C.

Note 2- Flash point determinations below 10°C and above 250°C can be performed; however, the precision has not been determined below and above these temperature.

1.5 If the user's specification requires a defined flash point method other than this test method, neither this test method nor any other method should be substituted for the prescribed method without obtaining comparative data and an agreement from the specifier.

1.6 The values stated in SI units are to be regarded as standard. Temperatures are in degrees Celsius, pressure in kilo-pascals. The values in parentheses are for information only.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Note 6.

Keywords

continuously closed cup; flammability; flash point; ICS Number Code 75.080 (Petroleum products in general)

To find similar documents by ASTM Volume:

05.02 (Petroleum Products and Lubricants (II): D3711 - D6122)

05.03 (Petroleum Products and Lubricants (III): D6138 - D6971)

To find similar documents by classification:

75.080 (Petroleum products in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D6450-16AR21

Revision Level

2016A R21 EDITION

Status

Current

Modification Type

New

Publication Date

July 27, 2021

Document Type

Test Method

Page Count

8 pages

Committee Number

D02.08