ASTM-D6474 Historical Revision Information
Standard Test Method for Determining Molecular Weight Distribution and Molecular Weight Averages of Polyolefins by High Temperature Gel Permeation Chromatography

ASTM-D6474 - 1999 R06 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Determining Molecular Weight Distribution and Molecular Weight Averages of Polyolefins by High Temperature Gel Permeation Chromatography
ORDER

Scope

1.1 This test method covers the determination of molecular weight distributions and molecular weight averages of linear polyolefins by high temperature gel permeation chromatography (GPC). This test method uses commercially available polystyrene standards and equipment and is applicable to polyethylenes (excluding high pressure low density polyethylene-LDPE) and polypropylenes soluble in 1,2,4-trichlorobenzene (TCB) at 140C. This test method is not absolute and requires calibration.

Note 1

Size exclusion chromatography (SEC) often is used as an alternative name for gel permeation chromatography (GPC).

Note 2

Specific methods and capabilities of users may vary with differences in columns, instrumentation, applications software, and practices between laboratories.

Note 3

One general method is outlined herein; alternative analytical practices can be followed and are attached in notes where appropriate.

Note 4

There is no similar or equivalent ISO standard.

1.2 The values stated in SI units, based on IEEE/ASTM S1-10, are to be regarded as the standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This test method measures the molecular weight distribution and molecular weight averages of polyethylene (except LDPE) and polypropylene resins. Differences in molecular weight and molecular weight distribution significantly affect physical properties, such as morphology, strength, melt flow etc., and as a result, the final properties of products made from these resins.

Keywords

gel permeation chromatography; molecular weight average; molecular weight distribution; polyolefin; size exclusion chromatography; ICS Number Code 83.080.20 (Thermoplastic materials)

To find similar documents by ASTM Volume:

08.03 (Plastics (III): D5117 - latest; Reinforced Plastic Piping Systems and Chemical Equipment; Plastic Building Products)

To find similar documents by classification:

83.080.20 (Thermoplastic materials)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D6474-99(2006)

Revision Level

1999 R06 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

April 1, 2006

Document Type

Test Method

Page Count

6 pages

Committee Number

D20.70