ASTM-D6513 Historical Revision Information
Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Endurance Tests

ASTM-D6513 - 2000 R05 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Calculating the Superimposed Load on Wood-frame Walls for Standard Fire-Resistance Tests
ORDER

Scope

1.1 This practice covers procedures for calculating the superimposed axial load required to be applied to load-bearing wood-frame walls throughout standard fire-endurance and fire and hose-stream tests.

1.2 The calculations determine the maximum load allowed by design for wood-frame wall assemblies under nationally recognized structural design criteria.

1.3 This practice is only applicable to those wood-frame assemblies for which the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS).

1.4 The system of units to be used is that of the nationally recognized structural design criteria. For the NDS, the units are inch-pound.

1.5 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Test Methods E 119 and E 1529, and other standard fire endurance test methods specify that throughout exposures to fire and the hose stream, a constant superimposed axial load be applied to a load-bearing test specimen to simulate a maximum load condition. They specify that this superimposed load shall be as nearly as practicable the maximum load allowed by design under nationally recognized structural design criteria. For this practice, the nationally recognized structural design criteria is the National Design Specification for Wood Construction (NDS).

4.1.1 Alternatively, the standard fire endurance test methods shall be conducted by applying an axial load that is less than the maximum allowable axial load as addressed by the NDS and this practice, but these tests shall be identified in the test report as being conducted under restricted load conditions. The superimposed axial load, as well as the superimposed axial load as a percentage of the maximum allowable axial design load as addressed by the NDS and this practice shall be included in the test report.

This practice describes procedures for calculating the superimposed axial load to be applied in standard fire endurance tests of wood-frame wall assemblies.

Statements in either the fire endurance test method standard or the nationally recognized structural design standard supercede any procedures described by this practice.

The NDS shall be consulted to ensure calculations are in compliance with all applicable provisions of that document.

Keywords

fire endurance; fire resistance; superimposed load; wall assembly; wood studs; ICS Number Code 13.220.50 (Fire-resistance of building materials and elements); 91.060.10 (Walls. Partitions. Facades)

To find similar documents by ASTM Volume:

04.10 (Wood)

To find similar documents by classification:

13.220.50 (Fire-resistance of building materials and elements)

91.060.10 (Walls. Partitions. Façades)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D6513-00(2005)

Revision Level

2000 R05 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Oct. 1, 2005

Document Type

Practice

Page Count

3 pages

Committee Number

D07.05