ASTM-D7282 Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements

ASTM-D7282 - 2021(E1) EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Setup, Calibration, and Quality Control of Instruments Used for Radioactivity Measurements
ORDER

Price:

$90.00        


Want this as a site license?

Scope

1.1 This practice covers consensus criteria for the calibration and quality control of nuclear instruments. This practice is provided for establishing appropriate quality control parameters at instrument startup, calibration of nuclear counting instruments and the continuing monitoring of quality control parameters. Calibrations are usually performed to establish the operating parameters of the instrument. This practice addresses the typically used nuclear counting instruments: alpha spectrometer, gamma spectrometer, gas proportional counter and liquid scintillation counter.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This practice is consistent with a performance-based approach wherein the frequency of re-calibration and instrument testing is linked to a laboratory’continuing performance with its quality control results. Under the premise of this practice, a laboratory demonstrates that its instrument performance is acceptable for analyzing sample test sources.

When a laboratory demonstrates acceptable performance based on continuing instrument quality control data (that is, QC charts), batch QC samples (that is, blanks, laboratory control samples, replicates, matrix spikes, and other batch QC samples as may be applicable) and independent reference materials, traditional schedule-driven instrument recalibration is permissible but unnecessary.

When continuing instrument QC, batch QC, or independent reference material sample results indicate that instrument response has exceeded established control or tolerance limits, instrument calibration is required. Other actions related to sample analyses on the affected instruments may be required by the laboratory QM.

The data obtained while following this Practice will most likely reside in computer storage. This data remains in the computer storage where it is readily retrievable and as necessary is used to produce plots, graphs, spreadsheets and other types of displays and reports. Frequency and performance of data storage backup should be specified in the laboratory QM.

Keywords

activity; alpha; beta; calibration; control chart; gamma; gas proportional; liquid scintillation; measurements; quality control; spectrometry; ICS Number Code 17.240 (Radiation measurements)

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IEC-60846-1
Radiation protection instrumentation - Ambient and/or directional dose equivalent (rate) meters and/or monitors for beta, X and gamma radiation - Part 1: Portable workplace and environmental meters and monitors

ASTM-F1158
Standard Guide for Inspection and Evaluation of Tampering of Security Seals

Document Number

ASTM-D7282-21E01

Revision Level

2021(E1) EDITION

Status

Current

Modification Type

New

Publication Date

Dec. 8, 2022

Document Type

Practice

Page Count

27 pages

Committee Number

D19.04