ASTM-D7980 Standard Guide for Ion-Chromatographic Analysis of Anions in Grab Samples of Ultrapure Water (UPW) in the Semiconductor Industry

ASTM-D7980 - 2015 R23 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Ion-Chromatographic Analysis of Anions in Grab Samples of Ultrapure Water (UPW) in the Semiconductor Industry
ORDER

Price:

$55.00        


Want this as a site license?

Scope

1.1 This guide applies to ultrapure water that is thought to contain low ppt (parts-per-trillion, weight/weight) levels of anionic contaminants (for example, bromide, chloride, fluoride, nitrate, nitrite, phosphate, and sulfate). To minimize carry-over problems between analyses, it is best to limit the concentration of any one contaminant to approximately 200 ppt (although this limit is only an approximation and may vary, depending on the user’s application).

1.2 This guide is intended to help analysts avoid contamination of ultrapure-water samples, since contamination control is the primary challenge when quantifying ppt-level anions in grab samples.

1.3 This guide does not include recommendations for collecting samples from the water source.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

4.1 This guide is intended to help analysts in the semiconductor industry. Examples of the usefulness of anion monitoring include: (1) determining when ion-exchange resin beds (in water-purification systems) need to be regenerated, and (2) ensuring that anion levels are low enough to allow the water to be used for the manufacture of semiconductor devices.

4.2 To ensure that the anions are indeed at low-ppt levels, it is recommended to check the conductivity of a subsample before proceeding with Section 5 of this guide. This check does not need to be exact; its purpose is simply to let the analyst know if the conductivity is higher than that of the highest-level standard solution being tested. Any high reading signifies that the sample, if analyzed, might contaminate the instrument.

Keywords

anions; contamination control; high purity; ion chromatography; trace analysis; ultrapure water;

To find similar documents by ASTM Volume:

11.01 (Water (I))

To find similar documents by classification:

71.060.01 (Inorganic chemicals in general)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D7980-15R23

Revision Level

2015 R23 EDITION

Status

Current

Modification Type

New

Publication Date

April 20, 2023

Document Type

Guide

Page Count

3 pages

Committee Number

D19.05