ASTM-D8052 Standard Test Method for Quantification of Air Leakage in Low-Sloped Membrane Roof Assemblies

ASTM-D8052 - 2022 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Quantification of Air Leakage in Low-Sloped Membrane Roof Assemblies
ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This test method provides a laboratory technique for determining air leakage in low-sloped membrane roof assemblies under specified negative air pressures differences.

1.2 This test method is intended to measure air leakage of a roof assembly with rooftop penetrations.

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

5.1 This test method can be useful in understanding the response of low-sloped membrane roof assemblies to air pressure differences induced across the assembly.

5.2 This test method can be useful in understanding the role of different roofing components in providing resistance to air leakage through the roof assembly.

5.3 When applying the results of tests by this test method, note that the performance of a roof or its components, or both, depends on proper installation.

5.4 This test method does not purport to establish all criteria necessary for the consideration of air movement in the design of a roof assembly. Air intrusion in roofing systems is separate and distinct from air leakage in roofing systems. Test Method D7586/D7586M provides an air intrusion test method for mechanically attached roof assemblies. The results are intended to be used for comparison purposes and likely do not represent the field installed performance of the roof assembly.

Keywords

air; air flow; air leakage; flow; flow meter; laboratory method; membrane; negative pressure; pressure; roof; wind pressure;

To find similar documents by ASTM Volume:

04.04 (Roofing and Waterproofing)

To find similar documents by classification:

91.100.50 (Binders. Sealing materials Including geomembranes, asphalts for buildings, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D8052_D8052M-22

Revision Level

2022 EDITION

Status

Current

Modification Type

New

Publication Date

Sept. 12, 2022

Document Type

Test Method

Page Count

8 pages

Committee Number

D08.20