ASTM-D8370 Standard Test Method for Field Measurement of Electrochemical Impedance on Coatings and Linings

ASTM-D8370 - 2022 EDITION - CURRENT


Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Field Measurement of Electrochemical Impedance on Coatings and Linings
ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This test method covers the procedure for field measurement of electrochemical impedance spectroscopy (EIS) for polymeric coatings over conductive substrates.

1.2 This test method covers the parameters for determining an adequate sample size.

1.3 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

4.1 This test method is suitable for in-service condition assessment and quality control (QC) testing.

4.2 This technique is used to investigate a polymer barrier coating over a conductive substrate and is limited to exposed and accessible coating surfaces.

4.3 This test method is applicable to polymer barrier coatings of all thicknesses provided the impedance is within equipment capabilities. Special considerations are required for evaluation of coatings exceeding 2 mm thickness or containing conductive media, such as metal pigments and conducting polymers.

4.4 This test method provides the experimental method needed to ensure proper application of field EIS testing and reporting of its results. This test method uses two test cells per measurement with no electrical connection to the substrate (1-4) (a deviation from the traditional three-electrode measurement) to prevent the need for electrical connection to the underlying structure.

Note 1: The two-test-cell method measures the impedances beneath the two cells plus the impedance of the path between them. This arrangement has additional risks of false negatives/positives that are not encountered using the traditional three-electrode measurement in which an electrical connection to the substrate is made. For this test method, a false positive is defined as a higher impedance value than is typical for the coating, and a false negative is defined as a lower impedance value than is typical for the coating. A traditional three-electrode measurement in the field is possible, but a reliable electrical connection to the substrate can be challenging and may require damage to an otherwise good coating.

4.5 This test method may be used at any time during the life of a coating system. If used for QC, allow for any manufacturer’s recommended cure or drying time unless otherwise agreed upon between the participating parties.

Note 2: The results obtained by using this test method could be used for informed coating maintenance decisions, for example, whether to replace a coating system, and may also be applicable as QC measurement for coating contracts.

4.6 The results obtained by using this test method shall not be considered as a means for estimating the structural properties of the underlying structure.

4.7 The results obtained by using this test method do not measure the corrosion susceptibility of the underlying structure because it uses two test cells with no electrical connection to the substrate. The open circuit potential and voltage perturbation are applied to the test cell electrode, per 5.3, and not the underlying structure.

4.8 The electrochemical impedance measurements shall be interpreted by engineers or technical specialists experienced in the fields of protective coatings and corrosion testing. It is often necessary to use other data such as visual inspection, dry film thickness, and adhesion testing, in addition to electrochemical impedance, to formulate conclusions concerning corrosion activity of the underlying structure or the remaining service life of the coating system. See Test Methods D660, D661, D714, or Practice D610 for more information on coating visual inspection.

Keywords

coating impedance; coating quality control; electrochemical impedance spectroscopy; EIS; field impedance; potentiostat;

To find similar documents by ASTM Volume:

06.02 (Paint -- Products and Applications; Protective Coatings; Pipeline Coatings)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D8370-22

Revision Level

2022 EDITION

Status

Current

Modification Type

New

Publication Date

March 24, 2022

Document Type

Test Method

Page Count

8 pages

Committee Number

D01.48