Standard Test Method for Analysis of Aluminum and Aluminum Alloys by Spark Atomic Emission Spectrometry
ORDER

Price:

$63.00        


Want this as a site license?

Changes from the previous issue

A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.

Scope

1.1 This test method describes the analysis of aluminum and its alloys by spark-atomic emission spectrometry (Spark-AES). The aluminum specimen to be analyzed may be in the form of a chill cast disk, casting, foil, sheet, plate, extrusion, or some other wrought form or shape. The elements covered in the scope of this method are listed in the table below.

Element

Tested Mass Fraction Range
(Wt %)

Antimony

   0.001 to 0.003

Arsenic

   0.001 to 0.006

Beryllium

   0.0004 to 0.24

Bismuth

   0.03 to 0.6

Boron

   0.0006 to 0.009

Calcium

   0.0002 to –

Chromium

   0.001 to 0.23

Cobalt

   0.4 to –

Copper

   0.001 to 5.5

Gallium

   0.02 to –

Iron

   0.2 to 0.5

Lead

   0.04 to 0.6

Lithium

   0.0003 to 2.1

Magnesium

   0.03 to 5.4

Manganese

   0.001 to 1.2

Nickel

   0.005 to 2.6

Phosphorus

   0.003 to –

Silicon

   0.07 to 16

Sodium

   0.003 to 0.02

Strontium

   0.03 to –

Tin

   0.03 to –

Titanium

   0.001 to 0.12

Vanadium

   0.002 to 0.022

Zinc

   0.002 to 5.7

Zirconium

   0.001 to 0.12

Note 1: The mass fraction ranges given in the above scope were established through cooperative testing (ILS) of selected reference materials. The range shown for each element does not demonstrate the actual usable analytical range for that element. The usable analytical range may be extended higher or lower based on individual instrument capability, spectral characteristics of the specific element wavelength being used, and the availability of appropriate reference materials.

Note 2: Mercury (Hg) is intentionally not included in the scope. Analysis of Hg in aluminum by Spark-AES is not recommended. Accurate analysis of Hg using this technique is compromised by the presence of an intense iron interference. Inaccurate reporting of Hg due to these interference effects can jeopardize the current designation of aluminum production as a mercury-free process. To demonstrate compliance with legislated Hg content limits, use of an alternate method capable of analysis with a minimum reporting limit of 0.0001% or lower is recommended. Suitable techniques include but are not limited to GD-MS, XRF (X-ray fluorescence), cold vapor AA, and ICP-MS.

1.2 This test method is suitable primarily for the analysis of chill cast disks as defined in Practices E716. Other forms may be analyzed, provided that: (1) they are sufficiently massive to prevent undue heating, (2) they allow machining to provide a clean, flat surface, which creates a seal between the specimen and the spark stand, and (3) reference materials of a similar metallurgical condition and chemical composition are available.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific safety and health statements are given in Section 10.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 The metallurgical properties of aluminum and its alloys are highly dependent on chemical composition. Precise and accurate analyses are essential to obtaining desired properties, meeting customer specifications, and helping to reduce scrap due to off-grade material.

5.2 This test method is applicable to chill cast specimens as defined in Practices E716 and can also be applied to other types of samples provided that suitable reference materials are available. Also, other sample forms can be melted and cast into a disk, using an appropriate mold, as described in Practices E716. However, it should be noted that some elements (for example, magnesium) readily form oxides, while some others (for example, sodium, lithium, calcium, and strontium) are volatile, and may be lost to varying degrees during the melting process.

Keywords

aluminum; aluminum alloys; Spark Atomic Emission Spectrometry (Spark-AES);; ICS Number Code 77.120.10 (Aluminium and aluminium alloys)

To find similar documents by ASTM Volume:

03.05 (Analytical Chemistry for Metals, Ores, and Related Materials: E 32 - latest)

To find similar documents by classification:

77.120.10 (Aluminium and aluminium alloys)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

ASTM-E10
Standard Test Method for Brinell Hardness of Metallic Materials

ASTM-E8
Standard Test Methods for Tension Testing of Metallic Materials

QPL-AMS-2644
Inspection Material, Penetrant

Document Number

ASTM-E1251-17a

Revision Level

2017A EDITION

Status

Current

Modification Type

Revision

Publication Date

Oct. 15, 2017

Document Type

Test Method

Page Count

10 pages

Committee Number

E01.04