ASTM-E1385 Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Steam Distillation (Withdrawn 2009)

ASTM-E1385 - 2000 EDITION - CANCELLED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Separation and Concentration of Ignitable Liquid Residues from Fire Debris Samples by Steam Distillation (Withdrawn 2009)

Scope

1.1 This practice covers the procedure for separating visible quantities of water insoluble hydrocarbons from samples of fire debris.

1.2 This practice is recommended only for samples which have a detectable odor of petroleum distillates when examined at room temperature.

1.3 This practice can yield useful extracts by the application of a solvent to the distillation trap in the event that only small quantities of hydrocarbons are obtained.

1.4 Alternate separation and concentration procedures are listed in the referenced documents.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Steam distillation is a classical separation technique, useful for preparing extracts for analysis by gas chromatography GC/MS or GC/IR. Distillates are suitable for analysis according to Test Method E 1387 or Guide E 1618.

The visible oily liquid extract can be used as a courtroom exhibit, unlike extracts produced by other separation procedures which are solutions rather than a neat liquid.

This practice is not useful for the separation of water soluble ignitable liquids such as alcohols or ketones.

Alternate separation and concentration methods are suggested if the concentration of flammable or combustible liquid residues is not detectable by odor.

This is a destructive technique that should only be used when a representative portion of the sample can be reserved for reanalysis. Those portions of the sample subjected to this procedure may not be suitable for resampling. Consider using passive headspace concentration as described in Practice E 1412.

Keywords

fire debris samples; steam distillation; ICS Number Code 71.040.40 (Chemical analysis)

To find similar documents by ASTM Volume:

14.02 (General Test Methods; Forensic Psychophysiology; Forensic Sciences; Terminology; Conformity Assessment; Statistical Methods; Nanotechnology; Forensic Engineering; Manufacture of Pharmaceutical Products)

To find similar documents by classification:

71.040.40 (Chemical analysis Including analysis of gases and surface chemical analysis)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1385-00

Revision Level

2000 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

Dec. 10, 2000

Document Type

Practice

Page Count

2 pages

Committee Number

E30.01