ASTM-E1602 Standard Guide for Construction of Solid Fuel Burning Masonry Heaters

ASTM-E1602 - 2003 R17 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Guide for Construction of Solid Fuel Burning Masonry Heaters
ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This guide covers the design and construction of solid fuel burning masonry heaters. It provides dimensions for site constructed masonry heater components and clearances that have been derived by experience and found to be consistent with the safe installation of those masonry heaters.

1.2 Values given in SI units are to be regarded as standard. Inch/pound units may be rounded (see IEEE/ASTM SI-10). All dimensions are nominal unless specifically stated otherwise. All clearances listed in this guide are actual dimensions.

1.3 This guide applies to the design and construction of masonry heaters built on-site with the components and materials specified herein. It does not apply to the construction/installation requirements for component systems that have been safety tested and listed. The requirements for listed masonry heater systems are specified in the manufacturer’s installation instructions.

1.4 The design and construction of solid fuel burning masonry heaters shall comply with applicable building codes.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

4.1 This guide can be used by code officials, architects, and other interested parties to evaluate the design and construction of masonry heaters. It is not restricted to a specific method of construction, nor does it provide all specific details of construction of a masonry heater. This guide does provide the principles to be followed for the safe construction of masonry heaters.

4.2 This guide is not intended as a complete set of directions for construction of masonry heaters.

4.3 Construction of masonry heaters is complex, and in order to ensure their safety and performance, construction shall be done by or under the supervision of a skilled and experienced masonry heater builder.5

Keywords

brick; Contraflow; firebrick; fire clay mortar; Grundofen; Kachelofen; Kakelugn; masonry heater; mortar; refractory mortar; Russian; soapstone refractory mortar;; ICS Number Code 25.180.20 (Fuel furnaces)

To find similar documents by ASTM Volume:

04.01 (Cement; Lime; Gypsum)

04.11 (Building Constructions (I): E72 - E2110)

To find similar documents by classification:

25.180.20 (Fuel furnaces)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1602-03(2017)

Revision Level

2003 R17 EDITION

Status

Current

Modification Type

Reapproval

Publication Date

Sept. 1, 2017

Document Type

Guide

Page Count

9 pages

Committee Number

E06.54