ASTM-E1607 Standard Practice for Use of the Alanine-EPR Dosimetry System (Withdrawn 2002)

ASTM-E1607 - 1996(E1) EDITION - CANCELLED -- See the following: ASTM-51607
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Use of the Alanine-EPR Dosimetry System (Withdrawn 2002)

Scope

1.1 This practice covers materials description, dosimeter preparation, instrumentation, and procedures for using the alanine-EPR dosimetry system for measuring the absorbed dose in materials irradiated with photons and electrons. The system is based on electron paramagnetic resonance (EPR) spectroscopy of the amino acid alanine. It is classified as a reference standard dosimetry system (see Guide E1261).

1.2 This practice covers alanine-EPR dosimetry systems for dose measurements under the following conditions:

1.2.1 The absorbed dose range is between 1 and 10 Gy.

1.2.2 The absorbed dose rate is up to 10 Gy s -1 for continuous radiation fields and up to 10 Gy s -1 for pulsed radiation fields (1, 2).

1.2.3 The radiation energy range for photons is between 0.1 and 50 MeV and for electrons is between 0.3 and 50 MeV (1, 2).

1.2.4 The irradiation temperature is between -60 and +90°C (2, 3).

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Absorbed radiation dose; Alanine dosimetry; Dosimetry; Electron beam; Electron paramagnetic (EPR) resonance; Electron spin resonance; EPR/ESR dosimetry; Gamma radiation; Ionizing radiation; Irradiance/irradiation; Photons; Radiation exposure; Reference standard dosimeter; X-ray monitoring; alanine-EPR dosimetry system-use; ICS Number Code 17.240 (Radiation measurements)

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1607-96e1

Revision Level

1996(E1) EDITION

Status

Cancelled

Modification Type

Replaced

Publication Date

June 1, 1999

Document Type

Practice

Page Count

7 pages

Committee Number

E10.01