This specification covers rigid closed-cell polyurethane and polyisocyanurate thermal insulation foams for application in sandwich structural panel cores used in shelter construction for exposure to specified ambient temperatures. The unfaced foam thermal insulation boards are classified into three types (Types 1, 2, 3, and 4) according to increasing nominal density. The morphology of the insulation shall consist of a multitude of individual cells of uniform size and dimension, essentially closed off from each other, homogeneous throughout, free of voids, accumulations of unexpanded material, foreign inclusions, or seams. Upon undergoing appropriate acceptance tests, sampled specimens should adhere accordingly to the limiting values set for the following physical and mechanical properties: density; thermal conductivity; compressive strength; shear strength; percent closed cell; linear and volumetric dimensional stability; flame resistance (extinguish time and burn distance); and impact resistance.
Scope
1.1 This specification covers rigid, closed cell, polyurethane and polyisocyanurate thermal insulation for sandwich panels used in shelter construction for exposure to ambient temperatures of −25 to 160 °F (−32 to 71 °C). Painted surfaces of shelters in actual field use reach temperatures of 200 °F (93 °C). The materials in this specification must be capable of withstanding processing, (laminating) temperatures of 230 °F (110 °C).
1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3 The following precautionary caveat pertains only to the test method portion, Section 12, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
Keywords
impact resistance; polyisocyanurate foam; polyurethane foam; relocatable shelters; rigid foam; sandwich panel; sandwich panel core; thermal insulation
To find similar documents by ASTM Volume:
04.11 (Building Constructions (I): E72 - E2110)
To find similar documents by classification:
91.100.99 (Other construction materials)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASTM-E84Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM-C591
Standard Specification for Unfaced Preformed Rigid Cellular Polyisocyanurate Thermal Insulation
ASTM-C518
Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
Document Number
ASTM-E1730-19
Revision Level
2019 EDITION
Status
Current
Modification Type
Revision
Publication Date
July 1, 2019
Document Type
Specification
Page Count
5 pages
Committee Number
E06.53