ASTM-E1956 Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing (Withdrawn 2002)

ASTM-E1956 - 1998 EDITION - CANCELLED -- See the following: ASTM-51956
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Use of Thermoluminescence-Dosimetry (TLD) Systems for Radiation Processing (Withdrawn 2002)

Scope

1.1 This practice covers procedures for the use of thermoluminescence dosimeters (TLDs) utilized as routine dosimeters to determine the absorbed dose in a material irradiated by ionizing radiation. Examples of materials useful as TLDs include LiF, CaF2, CaSO4, Li2B4O7 and Al2O3. Although some elements of the procedures have broader application, the specific area of concern is radiation processing of materials such as blood products, food, and insects for sterile release programs. This practice is applicable to the measurement of absorbed dose in materials irradiated by gamma rays, X rays, and electrons. Source energies covered are from 0.1 to 50 MeV photons and electrons. The range of absorbed dose covered is approximately from 1 to 105 Gy (102 to 107 rad), and the range of absorbed dose rates is approximately from 10-2 to 1010 Gy/s (1 to 1012 rad/s). Absorbed dose and absorbed dose-rate measurements in materials subjected to neutron irradiation are not covered in this practice.

1.2 Procedures for the use of TLDs for determining absorbed dose in radiation-hardness testing of electronic devices are given in Practice E 668.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

absorbed dose; dosimeter measurement; radiation processing; thermoluminescence dosimeter; thermoluminescence dosimetry system; TLD; ICS Number Code 17.240 (Radiation measurements)

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1956-98

Revision Level

1998 EDITION

Status

Cancelled

Modification Type

Replaced

Publication Date

June 10, 1998

Document Type

Practice

Page Count

8 pages

Committee Number

E10.01