Scope

1.1 This guide describes an approach to the validation process for a Laboratory Information Management System (LIMS).

1.2 This guide is for validation of a commercial LIMS purchased from a vendor. The procedures may apply to other types of systems, but this guide makes no claim to address all issues for other types of systems. Further, in-house developed LIMS, that is, those developed by internal or external programmers specifically for an organization, can utilize this guide. It should be noted that there are a number of related software development issues that this guide does not address. Users who embark on developing a LIMS either internally or with external programmers also should consult the appropriate ASTM, ISO, and IEEE software development standards.

1.3 This guide is intended to educate individuals on LIMS validation, to provide standard terminology useful in discussions with independent validation consultants, and to provide guidance for development of validation plans, test plans, required standard operating procedures, and the final validation report.

Significance and Use

Validation is an important and mandatory activity for laboratories that fall under regulatory agency review. Such laboratories produce data upon which the government depends to enforce laws and make decisions in the public interest. Examples include data to support approval of new drugs, prove marketed drugs meet specifications, enforce environmental laws, and develop forensic evidence for trial. This also extends to LIMS used in environmental laboratories. In some cases these systems may need to be interoperable with CLIMS and computer-based patient records (CPR) for reporting environmental exposures and clinical laboratory testing for biologic measure of stressor exposure. The enormous financial, legal, and social impact of these decisions requires government and public confidence in laboratory data. To ensure this confidence, government agencies regularly review laboratories operating under their rules to confirm that they are producing valid data. Computer system validation is a part of this review. This guide is designed to aid users validating LIMS and incorporating the validation process into their LIMS life cycle.

Validation must provide evidence of testing, training, audit and review, management responsibility, design control, and document control, both during the development of the system and its operation life (2).

Keywords

ICS Number Code 35.240.80 (IT applications in health care technology)

To find similar documents by ASTM Volume:

03.06 (Molecular Spectroscopy; Surface Analysis)

To find similar documents by classification:

35.240.80 (IT applications in health care technology Including computer tomography)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E2066-00(2007)

Revision Level

2000 R07 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

March 1, 2007

Document Type

Guide

Page Count

26 pages

Committee Number

E13.15