ASTM-E283 › Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method provides a standard laboratory procedure for determining the air leakage rates of exterior windows, curtain walls, and doors under specified differential pressure conditions across the specimen. The test method described is for tests with constant temperature and humidity across the specimen.
1.2 This laboratory procedure is applicable to exterior windows, curtain walls, and doors and is intended to measure only such leakage associated with the assembly and not the installation. The test method can be adapted for the latter purpose.
Note 1-Performing tests at non-ambient conditions or with a temperature differential across the specimen may affect the air leakage rate. This is not addressed by this test method.1.3 This test method is intended for laboratory use. Persons interested in performing field air leakage tests on installed units should reference Method E783.
1.4 Persons using this procedure should be knowledgeable in the areas of fluid mechanics, instrumentation practices, and shall have a general understanding of fenestration products and components.
1.5 Throughout this test method, SI units are listed first in accordance with
1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statement see Section 7.
Keywords
Air leakage testing-building materials/constructions; Building constructions/materials-curtain walls; Building constructions/materials-doors; Building constructions/materials-windows; Leak testing; Leak testing-building constructions/materials; air leakage through exterior windows/curtain walls/doors under specified; pressure differences across specimen, test; ICS Number Code 91.120.10 (Thermal insulation of buildings)
To find similar documents by ASTM Volume:
04.11 (Building Constructions (I): E72 - E2110)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
ASME-A17.1Safety Code for Elevators and Escalators (Co-numbered ASME A17.1-2016/CSA B44-16)
MIL-STD-130
Identification Marking of U.S. Military Property
AIHA-Z9.5
Laboratory Ventilation
Document Number
ASTM-E0283_E0283M-19
Revision Level
2019 EDITION
Status
Current
Modification Type
Reapproval
Publication Date
Aug. 1, 2019
Document Type
Test Method
Page Count
7 pages
Committee Number
E06.51