ASTM-F2079 Historical Revision Information
Standard Test Method for Measuring Intrinsic Elastic Recoil of Balloon-Expandable Stents

ASTM-F2079 - 2002 R08 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measuring Intrinsic Elastic Recoil of Balloon-Expandable Stents
ORDER

Scope

1.1 The purpose of this test method is to quantify the percentage by which the diameter of a stent decreases from its expanded diameter while still on the delivery balloon to its relaxed diameter after deflating the balloon. This test method is appropriate for stents manufactured from a material that is plastically deformed when the stent's diameter is increased from its predeployed size to its postdeployed size by mechanical means. This test method may be performed in air at room temperature unless there is a known temperature dependence of the material, in which case, the temperature at which the test is conducted shall be stated in the report.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

Minimal stent recoil is a desirable feature of a stent because it minimizes the maximum diameter to which a stent must be expanded to achieve its final relaxed diameter. A stent having a high recoil must be expanded to a greater diameter to achieve its final relaxed diameter than a stent having low recoil. Practically, excessive expansion of the vessel into which the stent is to be implanted may cause tissue damage resulting in a poor immediate result or poor long-term outcome. Stent recoil is affected by intrinsic properties of the material used to construct the stent and the specific geometric design of the stent; therefore, measuring stent recoil is an essential part of evaluating the design.

Keywords

recoil; stent; Angioplasty; Balloon-expandable stents; Characteristics/characterization--surgical implants/applications; Coronary artery; Intrinsic elastic recoil; Nominal diameter (in materials/analysis); Performance--surgical materials/applications; Recoil; Stents; Vascular stents; ICS Number Code 11.040.20 (Transfusion, Infusion)

To find similar documents by ASTM Volume:

13.01 (Medical and Surgical Materials and Devices)

To find similar documents by classification:

11.040.20 (Transfusion, infusion and injection equipment Including blood packs Syringes, needles and catheters, see 11.040.25)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-F2079-02(2008)

Revision Level

2002 R08 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

June 1, 2008

Document Type

Test Method

Page Count

3 pages

Committee Number

F04.30