This specification covers total knee replacement (TKR) prostheses used to provide functioning articulation by employing femoral and tibial components, allowing a minimum of 110° of flexion to high flexion. Replaceable components of modular designs, for example, tibial articulating surfaces and all components labeled for or capable of being used with cement, regardless of whether the same components can also be used without cement are described. Primary and revision prostheses and also covers fixed and mobile bearing knee designs are discussed. Basic descriptions of material and prosthesis geometry are provided. Additionally, those characteristics determined to be important to in vivo performance of the prosthesis are defined. The prostheses are classified into three kinds according to degree of constraint. The first kind is considered constrained which prevents dislocation of the prosthesis in more than one anatomic plane and consists of either a single, flexible, across-the-joint component or more than one component linked together or affined. The second one is a semiconstrained joint prosthesis which limits translation or rotation, or both, of the prosthesis in one or more planes via the geometry of its articulating surfaces. It has no across-the-joint linkages. The third kind is a nonconstrained joint prosthesis which minimally restricts prosthesis movement in one or more planes. Its components have no across-the-joint linkages. The choice of materials is understood to be a necessary but not sufficient assurance of function of the device made from them. All devices shall be fabricated from materials with adequate mechanical strength and durability, corrosion resistance, and biocompatibility.

Scope

1.1 This specification is intended to cover all the widely used generic types of knee replacement prostheses used to provide functioning articulation. This includes total knee replacement (TKR) and unicondylar knee replacement (UKR) prostheses of both fixed and mobile bearing varieties, and for primary or revision surgeries. Although a patellar component may be considered an integral part of a TKR, the detailed description of this component is excluded here since it is provided in Specification F1672.

1.2 Included within the scope of this specification are replaceable components of modular designs, for example, tibial articulating surfaces and all components labeled for, or capable of, being used with cement, regardless of whether the same components can also be used without cement.

1.3 This specification is intended to provide basic descriptions of material and prosthesis geometry. Additionally, those characteristics determined to be important to in-vivo performance of the prosthesis are defined. However, compliance with this specification does not itself define a device that will provide adequate clinical performance.

1.4 Excluded from the scope are hemiarthroplasty devices that replace only the femoral or tibial surface, but not both; and patellofemoral prostheses. Also excluded are devices designed for custom applications.

1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Keywords

arthroplasty; contact area; contact pressure; fatigue; knee; knee constraint; knee prosthesis; knee wear; particles; surface roughness; total knee replacement; TKR; unicondylar knee replacement (UKR); UHMWPE;

To find similar documents by ASTM Volume:

13.01 (Medical and Surgical Materials and Devices)

To find similar documents by classification:

11.040.40 (Implants for surgery, prosthetics and orthotics Including pacemakers Ophthalmic implants, see 11.040.70)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

ASTM-A479
Standard Specification for Stainless Steel Bars and Shapes for Use in Boilers and Other Pressure Vessels

ASTM-A240
Standard Specification for Chromium and Chromium-Nickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications

ASTM-A276
Standard Specification for Stainless Steel Bars and Shapes

Document Number

ASTM-F2083-21

Revision Level

2021 EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

Feb. 3, 2021

Document Type

Specification

Page Count

10 pages

Committee Number

F04.22