ASTM-G187 Historical Revision Information
Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method

ASTM-G187 - 2012A EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measurement of Soil Resistivity Using the Two-Electrode Soil Box Method
ORDER

Scope

1.1 This test method covers the equipment and procedures for the measurement of soil resistivity, for samples removed from the ground, for use in the assessment and control of corrosion of buried structures.

1.2 Procedures allow for this test method to be used in the field or in the laboratory.

1.3 The test method procedures are for the resistivity measurement of soil samples in the saturated condition and in the as-received condition.

1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. Soil resistivity values are reported in ohm-centimeter.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.

Significance and Use

5.1 The resistivity of the surrounding soil environment is a factor in the corrosion of underground structures. High resistivity soils are generally not as corrosive as low resistivity soils. The resistivity of the soil is one of many factors that influence the service life of a buried structure. Soil resistivity may affect the material selection and the location of a structure.5

5.2 Soil resistivity is of particular importance and interest in the corrosion process because it is basic in the analysis of corrosion problems and the design of corrective measures.

5.3 The test method is focused to provide an accurate, expeditious measurement of soil resistivity to assist in the determination of a soil’s corrosive nature. Test Method G57 emphasizes an in situ measurement commonly utilized in the design of a buried structures’ corrosion control (cathodic protection systems’ ground bed design, and so forth). The two-electrode soil box method often compliments the four-pin, in situ soil resistivity method.

5.4 The saturated soil resistivity determined by this test method does not necessarily indicate the minimum soil resistivity.

Keywords

soil box; soil box factor; soil resistivity; two-electrode soil box; ICS Number Code 13.080.99 (Other standards related to soil quality)

To find similar documents by ASTM Volume:

03.02 (Corrosion of Metals; Wear and Erosion)

To find similar documents by classification:

13.080.99 (Other standards related to soil quality Including agricultural aspects related to soils and re-use of soil materials)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-G187-12a

Revision Level

2012A EDITION

Status

Superseded

Modification Type

Revision

Publication Date

March 1, 2013

Document Type

Test Method

Page Count

6 pages

Committee Number

G01.10