IEC-61800-5-2 Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional

IEC-61800-5-2 - EDITION 2.0 - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:


IEC 61800-5-2:2016 specifies requirements and makes recommendations for the design and development, integration and validation of safety related power drive systems (PDS(SR)) in terms of their functional safety considerations. It applies to adjustable speed electrical power drive systems covered by the other parts of the IEC 61800 series of standards as referred in IEC 61800-2. IEC 61800-5-2, which is a product standard, sets out safety-related considerations of PDS(SR)s in terms of the framework of IEC 61508, and introduces requirements for PDS(SR)s as subsystems of a safety-related system. It is intended to facilitate the realisation of the electrical/ electronic/programmable electronic (E/E/PE) parts of a PDS(SR) in relation to the safety performance of safety sub-function(s) of a PDS. This edition includes the following significant technical changes with respect to the previous edition:
a) rational added in the scope why low demand mode is not covered by this standard,
b) definition added for: "category" and "safety function",
c) "Other sub-functions" sorted into "Monitoring sub-functions" and "Output functions",
d) deleted "proof test" throughout the document because for PDS(SR) a proof test is not applicable,
e) replaced the term "safety function" by "safety sub-function" throughout the document,
f) Updated references to IEC 61508 series Ed.2010,
g) Added the principle rules of ISO 13849-1 and reference to tables of ISO 13849-2,
h) 6.1.6 Text replaced by Table 2,
i) 6.1.7 Integrated circuits with on-chip redundancy matched to changed requirement in IEC 61508-2: 2010, Annex E,
j) 6.2.8 Design requirements for thermal immunity of a PDS(SR)
k) 6.2.9 Design requirements for mechanical immunity of a PDS(SR),
l) 6.1.6 SIL for multiple safety sub-functions within one PDS(SR),
m) 6.1.7 Integrated circuits with on-chip redundancy,
n) 6.2.1 Basic and well-tried safety principles,
o) 6.2.2.1.4 Diagnostic test interval when the hardware fault tolerance is greater than zero,
p) 6.2.5.2.7 PDS(SR) parameterization,
q) 9 Test requirements,
r) 9.3 Electromagnetic (EM) immunity testing,
s) 9.4 Thermal immunity testing,
t) 9.5 Mechanical immunity testing,
u) Annex A Sequential task table,
v) Annex D, D.3.16, Motion and position feedback sensors updated,
w) Annex E Electromagnetic immunity (EM) requirement for PDS(SR),
x) Annex F Estimation of PFDavg value for low demand with given PFH value.
ORDER

Price:

$430.68        


Want this as a site license?

To find similar documents by classification:

13.110 (Safety of machinery This group includes standards for general use)

29.200 (Rectifiers. Converters. Stabilized power supply Including semiconductor converters)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

MIL-STD-810
Environmental Engineering Considerations and Laboratory Tests

BS-EN-61000-4-8
Electromagnetic compatibility (EMC)

IEC-61558-1
Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests

Document Number

IEC 61800-5-2 Ed. 2.0 b:2016

Revision Level

EDITION 2.0

Status

Current

Publication Date

April 1, 2016

Committee Number

22G