SS-EN-303-5 Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking

SS-EN-303-5 - 2021/A1 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


1.1 General This European Standard applies to heating boilers including safety devices up to a nominal heat output of 500 kW which are designed for the burning of solid fuels only and are operated according to the instructions of the boiler manufacturer. This European Standard deals with significant hazards, hazardous situations and events relevant to heating boilers used as intended and under the conditions foreseen by the manufacturer (see Clause 4). The boilers may operate under natural draught or forced draught. The stoking may work manually or automatically. The boilers may operate under room sealed conditions in case of supervised under pressure in the combustion chamber. The boilers may operate in condensing condition. NOTE This European Standard deals with boilers which are both within and outside of the scope of the Machinery Directive 2006/42/EC. This European Standard contains requirements and test methods for safety, combustion quality, operating characteristics, marking and maintenance of heating boilers and secondary emission reduction appliances and efficiency improvement appliances. It also covers all external equipment that influences the safety systems (e.g. back burning safety device, integral fuel hopper). This European Standard covers only boilers that include burners as a unit. The standard applies to the combination of a boiler body with a solid fuel burner according to EN 15270 as a unit only when the whole unit is tested in accordance with this European Standard. Heating boilers in accordance with this European Standard are designed for central heating installations where the heat carrier is water and the maximum allowable temperature is 110 °C, and which can operate at a maximum allowable operating pressure of 6 bars. For heating boilers with a built-in or attached water heater (storage or continuous flow heater), this European Standard only applies to those parts of the water heater which are necessarily subject to the opera...

To find similar documents by classification:

01.040.91 (Construction materials and building (Vocabularies))

27.060.30 (Boilers and heat exchangers Including steam pressure vessels Heat exchangers for medical use, see 11.040.10 Heat exchangers for the chemical industry, see 71.120.30 Heat exchangers for the petroleum and natural gas industry, see 75.180.20 Heating appliances for buildings, see 97.100)

91.140.10 (Central heating systems Including burners and boilers for central heating systems Heating appliances, see 97.100)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

ORDER

Price:

$235.50        


Want this as a site license?



Designation Name

SS-EN 303-5:2021+A1:2022

Revision Level

2021/A1 EDITION

Status

Current

Publication Date

Nov. 21, 2022

Language(s)

English

Page Count

108

International Equivalent

EN 303-5:2021+A1:2022(IDT)