SS-ISO-19581 › Measurement of radioactivity - Gamma emitting radionuclides - Rapid screening method using scintillation detector gamma-ray spectrometry (ISO 19581:2017, IDT)
SS-ISO-19581
-
2018 EDITION
-
CURRENT
Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:
The following bibliographic material is provided to assist you with your purchasing decision:
This document specifies a screening test method to quantify rapidly the activity concentration of gamma-emitting radionuclides, such as 131I, 132Te, 134Cs and 137Cs, in solid or liquid test samples using gamma-ray spectrometry with lower resolution scintillation detectors as compared with the HPGe detectors (see IEC 61563). This test method can be used for the measurement of any potentially contaminated environmental matrices (including soil), food and feed samples as well as industrial materials or products that have been properly conditioned. Sample preparation techniques used in the screening method are not specified in this document, since special sample preparation techniques other than simple machining (cutting, grinding, etc.) should not be required. Although the sampling procedure is of utmost importance in the case of the measurement of radioactivity in samples, it is out of scope of this document; other international standards for sampling procedures that can be used in combination with this document are available (see References [1],[2],[3],[4],[5],[6]). The test method applies to the measurement of gamma-emitting radionuclides such as 131I, 134Cs and 137Cs. Using sample sizes of 0,5 l to 1,0 l in a Marinelli beaker and a counting time of 5 min to 20 min, decision threshold of 10 Bq·kg-1 can be achievable using a commercially available scintillation spectrometer [e.g. thallium activated sodium iodine (NaI(Tl)) spectrometer 2 ? × 2 detector size, 7 % resolution (FWHM) at 662 keV, 30 mm lead shield thickness]. This test method also can be performed in a makeshift laboratory or even outside a testing laboratory on samples directly measured in the field where they were collected. During a nuclear or radiological emergency, this test method enables a rapid measurement of the sample activity concentration of potentially contaminated samples to check against operational intervention levels (OILs) set up by decision makers that would trigger a predeter...
To find similar documents by classification:
17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Designation Name
SS-ISO 19581:2018
Revision Level
2018 EDITION
Status
Current
Publication Date
March 20, 2018
Language(s)
English
Page Count
32
International Equivalent
ISO 19581:2017(IDT)