Standard Specification for Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe

ASTM-C506 - 2010 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts. The aggregate shall be so sized, graded, proportioned, and mixed with such proportions of Portland cement, blended hydraulic cement, or Portland cement and supplementary cementing materials, or admixtures, or a combination thereof, if used, and water to produce a homogeneous concrete mixture of such quality that the pipe will conform to the test and design requirement. The combination of cementitious materials used in the concrete shall be one of the following: Portland cement only, Portland blast furnace slag cement only, slag modified Portland cement only, Portland pozzolan cement only, a combination of Portland cement and ground- granulated blast-furnace slag, a combination of Portland cement and fly ash or a combination of Portland cement, ground granulated blast-furnace slag and fly ash. The materials shall undergo external load crushing strength test, compression test and absorption test. They shall also conform to the required internal dimensions, wall thickness, length of two opposite sides, length of pipe, position or area of reinforcement.

ORDER

Scope

1.1 This specification covers reinforced arch-shaped concrete pipe to be used for the conveyance of sewage, industrial wastes, storm water, and for the construction of culverts.

1.2 This specification is the inch-pound companion to C506M; therefore, no SI equivalents are presented in the specification.

Note 1—This specification is a manufacturing and purchase specification only, and does not include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe. However, experience has shown that the successful performance of this product depends upon the proper selection of the class of pipe, type of bedding and backfill, and care that the installation conforms to the construction specifications. The owner of the reinforced concrete pipe specified herein is cautioned that he must correlate the field requirements with the class of pipe specified and provide inspection at the construction site.

Keywords

arch pipe; culvert; D-load; reinforced concrete; sewer pipe; storm drain; Concrete pipe (reinforced)--specifications; Culvert pipe (concrete)--specifications; Sewer pipe (concrete)--specifications; Storm sewer/drainage concrete pipe--specifications; ICS Number Code 23.040.50 (Pipes and fittings of other materials)

To find similar documents by ASTM Volume:

04.05 (Chemical-Resistant Nonmetallic Materials; Vitrified Clay Pipe; Concrete Pipe; Fiber-Reinforced Cement Products; Mortars and Grouts; Masonry; Precast Concrete)

To find similar documents by classification:

23.040.50 (Pipes and fittings of other materials)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-C506-10

Revision Level

2010 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Feb. 1, 2010

Document Type

Specification

Page Count

7 pages

Committee Number

C13.02