ASTM-D3609 Standard Practice for Calibration Techniques Using Permeation Tubes

ASTM-D3609 - 2022 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Calibration Techniques Using Permeation Tubes
ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This practice describes a means for using permeation tubes for dynamically calibrating instruments, analyzers, and analytical procedures used in measuring concentrations of gases or vapors in atmospheres (1, 2).2

1.2 Typical materials that may be sealed in permeation tubes include: sulfur dioxide, nitrogen dioxide, hydrogen sulfide, chlorine, ammonia, propane, and butane (1).

1.3 The values stated in SI units are to be regarded as standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 Most analytical methods used in air pollutant measurements are comparative in nature and require calibration or standardization, or both, often with known blends of the gas of interest. Since many of the important air pollutants are reactive and unstable, it is difficult to store them as standard mixtures of known concentration for extended calibration purposes. An alternative is to prepare dynamically standard blends as required. This procedure is simplified if a constant source of the gas of interest can be provided. Permeation tubes provide this constant source, if properly calibrated and if maintained at constant temperature. Permeation tubes have been specified as reference calibration sources, for certain analytical procedures, by the Environmental Protection Agency (3).

Keywords

analyzers; butane permeation tubes; calibration; CL2 permeation tubes; gas permeable tubes; H2S permeation tubes; NH3 permeation tubes; NO2 permeation tubes; propane permeation tubes; SO2 permeation tubes ;

To find similar documents by ASTM Volume:

11.07 (Atmospheric Analysis)

To find similar documents by classification:

17.020 (Metrology and measurement in general Including measuring instruments in general, preferred numbers, standard measures, general aspects of reference materials, etc. Quantities and units, see 01.060 Chemical reference materials, see 71.040.30)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D3609-22

Revision Level

2022 EDITION

Status

Current

Modification Type

Revision

Publication Date

Dec. 8, 2022

Document Type

Practice

Page Count

5 pages

Committee Number

D22.01