ASTM-D3689 › Standard Test Methods for Deep Foundations Under Static Axial Tensile Load
The following bibliographic material is provided to assist you with your purchasing decision:
Scope
1.1 This test method covers procedures for testing vertical or batter piles, individually or in groups, to determine response of the pile or pile group to a static tensile load applied axially to the pile or pile group. This test method is applicable to all deep foundation units that function in a manner similar to piles, regardless of their method of installation. This test method is divided into the following sections:
Section Referenced Documents 2 Significance and Use 3 Apparatus for Applying Loads 4 Apparatus for Measuring Movements 5 Safety Precautions 6 Loading Procedures 7 Procedures for Measuring Movements 8 Report 9 Precision and Bias 101.2 This test method only describes procedures for testing single piles or pile groups. It does not cover the interpretation or analysis of the test results or the application of the test results to foundation design. See Appendix
1.3 Apparatus and procedures designated "optional" are to be required only when included in the project specifications and, if not specified, may be used only with the approval of the engineer responsible for the foundation design. The word "shall" indicates a mandatory provision and "should" indicates a recommended or advisory provision. Imperative sentences indicate mandatory provisions. Notes and illustrations included herein are explanatory or advisory.
1.4 Wherever in this test method the term pile is used with reference to the test pile, it shall include test pile groups.
1.5 The values stated in inch-pound units are to be regarded as the standard.
1.6 This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 6.
Keywords
Batter piles; Piles; Steel piles; Tension (tensile) properties/tests-soil/rock/related materials; Uplift capacity/pressure; Vertical piles; vertical/batter piles (individually/in groups)-under static axial; tensile load, test; ICS Number Code 93.020 (Earth works. Excavations. Foundation construction. Underground works)
To find similar documents by ASTM Volume:
04.08 (Soil and Rock (I): D420 - D5876)
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
MIL-STD-454Standard General Requirements for Electronic Equipment (Superseded by MIL-HDBK-454)
29CFR(1926)
Labor
MIL-C-46168
Coating, Aliphatic Polyurethane, Chemical Agent Resistant (See Notice 1 for Replacement Information)
Document Number
ASTM-D3689_D3689M-22
Revision Level
2022 EDITION
Status
Current
Modification Type
Withdrawn
Publication Date
Feb. 25, 2022
Document Type
Test Method
Page Count
14 pages
Committee Number
D18.11