ASTM-D5019 Standard Specification for Reinforced CSM (Chlorosulfonated Polyethylene) Sheet Used in Single-Ply Roof Membrane (Withdrawn 2011)

ASTM-D5019 - 2007A EDITION - CANCELLED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This specification covers fiber or fabric reinforced non-vulcanized polymeric sheet made from chlorosulfonated polyethylene (CSM) intended for use as a single-ply roof membrane exposed to the weather. In-place roof systems design criteria such as fire resistance, field seaming strength, impact/puncture resistance, material compatibility, and uplift resistance, among others, are beyond the scope of this specification. Backed or reinforced sheets shall conform to the following physical properties: thickness; breaking strength; elongation; tearing strength; low temperature bend; linear dimensional change; ply adhesion; hydrostatic resistance; ozone resistance; and weather resistance. On the other hand, coating portions on the weather side of the sheet containing neither backing nor internal reinforcement shall adhere to the following physical properties: tensile strength; elongation; tear resistance; ozone resistance; and water absorption.

Scope

1.1 This specification covers reinforced non-vulcanized polymeric sheet made from chlorosulfonated polyethylene (CSM) (see Note 1 ) intended for use as a single-ply roof membrane exposed to the weather. The sheet shall be reinforced with fiber or fabric.

Note 1

The term CSPE for chlorosulfonated polyethylene is commonly used in the roofing industry.

1.1.1 The polymers used in these sheets have thermoplastic characteristics at time of installation. The chlorosulfonated polyethylene will vulcanize in place under ambient conditions.

1.2 The tests and property limits used to characterize these sheets are minimum values.

1.2.1 In-place roof systems design criteria such as fire resistance, field seaming strength, impact/puncture resistance, material compatibility, and uplift resistance, among others, are factors that must be considered, but are beyond the scope of this specification.

1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

1.4 The following precautionary caveat pertains to the test methods portion only, Section 8, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

CSM (chlorosulfonated polyethylene); CSPE (chlorosulfonated polyethylene); flexible sheet; reinforcing fabrics; single-ply roof membrane; ICS Number Code 91.100.50 (Binders. Sealing materials)

To find similar documents by ASTM Volume:

04.04 (Roofing and Waterproofing)

To find similar documents by classification:

91.100.50 (Binders. Sealing materials Including geomembranes, asphalts for buildings, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D5019-07a

Revision Level

2007A EDITION

Status

Cancelled

Modification Type

Withdrawn

Publication Date

Nov. 1, 2007

Document Type

Specification

Page Count

4 pages

Committee Number

D08.18