ASTM-D5246 Historical Revision Information
Standard Test Method for Isolation and Enumeration of Pseudomonas aeruginosa from Water

ASTM-D5246 - 2015 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Isolation and Enumeration of Pseudomonas aeruginosa from Water
ORDER

Changes from the previous issue

A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.

Scope

1.1 The test method covers the isolation and enumeration of Pseudomonas aeruginosa. Testing was performed on spiked samples using reagent grade water as the diluent from surface waters; recreational waters; ground water, water supplies; especially rural nonchlorinated sources; waste water; and saline waters. The detection limit of this test method is one microorganism per 100 mL.

1.2 This test method was used successfully with reagent water. It is the user's responsibility to ensure the validity of this test method for surface waters, recreational waters, ground water, rural nonchlorinated sources; waste water; and saline waters.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 10.

Significance and Use

5.1 Pseudomonas aeruginosa is an opportunistic pathogen, and has been linked as the causative agent of numerous infections that may be transmitted through a contaminated water supply to a susceptible host.

Note 1: Fecal waste is >95 % E. coli which is found in humans and warm bloodied animals.

5.2 The membrane filtration procedure described is a rapid and reliable test method of detecting P. aeruginosa in water.

Keywords

.; enumeration; membrane filtration; Pseudomonas aeruginosa ;; ICS Number Code 07.100.20 (Microbiology of water)

To find similar documents by ASTM Volume:

11.02 (Water (II))

To find similar documents by classification:

07.100.20 (Microbiology of water Examination of biological properties of water, see 13.060.70)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D5246-15

Revision Level

2015 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Feb. 15, 2016

Document Type

Test Method

Page Count

5 pages

Committee Number

D19.24