Scope

1.1 This test method provides a laboratory technique for determining the air intrusion in low-sloped mechanically attached membrane roof assemblies under specified negative air pressures differences.

1.2 This test method is intended to measure only air intrusion associated with the opaque roof assembly free from penetrations such as those associated with mechanical devices, roof junctions, and terminations.

1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

This test method can be useful in understanding the response of low-sloped mechanically attached membrane roofing assemblies to air pressure differences induced across the assembly.

This test method can be useful in understanding the role of different roofing components in providing resistance to air intrusion into the membrane roofing assembly.

When applying the results of tests by this test method, note that the performance of a roof or its components, or both, may be a function of proper installation and adjustment.

This test method subjects the roof specimen to negative static pressures, as it is difficult to simulate the complex environmental conditions that can be encountered in service, including rapidly changing pressures due to wind gusting.

This test method does not purport to establish all criteria necessary for the consideration of air intrusion in the design of a roof assembly. The results are intended to be used for comparison purposes and may not represent the field installed performance of the roof assembly.

Keywords

air; air flow; air intrusion; air leakage; flow; flow meter; laboratory method; membrane; negative pressure; pressure; roof; wind pressure

To find similar documents by ASTM Volume:

04.04 (Roofing and Waterproofing)

To find similar documents by classification:

91.100.50 (Binders. Sealing materials Including geomembranes, asphalts for buildings, etc.)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D7586/D7586M-11

Revision Level

2011 EDITION

Status

Superseded

Modification Type

Withdrawn

Publication Date

March 1, 2011

Document Type

Test Method

Page Count

8 pages

Committee Number

D08.20