ASTM-D7989 Standard Practice for Demonstrating Equivalent In-Plane Lateral Seismic Performance to Wood-Frame Shear Walls Sheathed with Wood Structural Panels

ASTM-D7989 - 2021 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Demonstrating Equivalent In-Plane Lateral Seismic Performance to Wood-Frame Shear Walls Sheathed with Wood Structural Panels
ORDER

Price:

$63.00        


Want this as a site license?

Scope

1.1 This practice establishes a method for alternative shear wall systems to compare seismic equivalency parameters (SEP) derived from cyclic in-plane racking tests to performance targets derived from tests of light-frame shear walls constructed with wood structural panel (WSP) sheathing attached to dimension lumber framing using nails.

1.2 This practice considers only the performance of shear walls subject to cyclic lateral loading, parallel to the plane of the shear wall. Design of walls with openings and performance for other wall functions, such as out-of-plane bending, combined shear and uplift, and so forth are not considered.

1.3 This practice is applicable only to shear walls where all vertical-load-supporting elements are intact at the end of the in-plane lateral load test and remain capable of supporting gravity loads. Wall assemblies whose vertical-load-supporting elements buckle or otherwise become incapable of supporting gravity loads during the lateral load test are outside the scope of this practice. In addition, for bearing wall systems, this practice assumes that the shear wall system under evaluation has documented design procedures to ensure that vertical-load-supporting elements have adequate resistance to the combined effect of compression loads caused by overturning and gravity loads.

1.4 This practice does not address height limitations, detailing requirements, wall openings, derivation of design values for strength and stiffness, or other requirements and limitations that may be necessary for an alternative shear wall system. These requirements shall be provided elsewhere, such as by a suitable product standard for the alternative shear wall system.

1.5 This practice assumes that the stiffness or deformation of the alternative shear wall system can be estimated, and that design loads within a structure will be distributed among seismically equivalent wall systems based on their relative stiffness.

1.6 This practice is not intended to preclude other rational means of evaluating seismic performance.

1.7 This practice assumes that the alternative shear wall system may be used alone or in combination with wood-frame shear walls sheathed with wood structural panels.

1.8 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.9 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.10 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 This practice documents cyclic performance benchmarks for shear walls constructed with wood structural panel (WSP) sheathing attached to dimension lumber framing using common or galvanized box nails as defined in 3.2.8.

5.2 Procedures described in this practice provide a method to evaluate an alternative shear wall system’s SEPs to demonstrate equivalent in-plane lateral seismic performance to the reference shear wall system.

5.3 The procedures described in this practice do not address all factors to be considered for recognition of an alternative shear wall system. Such factors, as described in 1.4, vary by the end-use application and shall be addressed outside the scope of this standard through an evaluation of the acceptability of the alternative shear wall system in accordance with requirements of building codes and standards, as applicable.

Keywords

cyclic loads; earthquake, shear wall; lateral force; seismic; wood structural panel; ;

To find similar documents by ASTM Volume:

04.10 (Wood)

To find similar documents by classification:

79.060.01 (Wood-based panels in general)

91.060.10 (Walls. Partitions. Façades)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-D7989-21

Revision Level

2021 EDITION

Status

Current

Modification Type

Revision

Publication Date

Nov. 24, 2021

Document Type

Practice

Page Count

10 pages

Committee Number

D07.05