Scope

1.1 This test method covers the determination of the resistance of installed exterior windows, curtain walls, skylights, and doors to water penetration when water is applied to the outdoor face and exposed edges simultaneously with a static air pressure at the outdoor face higher than the pressure at the indoor face.

1.2 This test method is applicable to any curtain-wall area or to windows, skylights, or doors alone. It is intended primarily for determining the resistance to water penetration through such assemblies for compliance with specified performance criteria, but it may also be used to determine the resistance to penetration through the joints between the assemblies and the adjacent construction. Other procedures may be appropriate to identify sources of leakage.

1.3 This test method addresses water penetration through a manufactured assembly. Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. This test method does not address these issues.

1.4 The proper use of this test method requires a knowledge of the principles of pressure measurement.

1.5 The values stated in SI units are to be regarded as the standard. The inch-pound equivalents of SI units may be approximate.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see 7.1.

Keywords

curtain walls; doors; skylights; water penetration; windows; ICS Number Code 91.060.50 (Doors and windows)

To find similar documents by ASTM Volume:

04.11 (Building Constructions (I): E72 - E2110)

To find similar documents by classification:

91.060.50 (Doors and windows Including doorsets, their components, blinds, shutters Door and window hardware, see 91.190)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

MIL-B-24480
Bronze, Nickel-Aluminum (Uns No. C95800) Castings for Seawater Service

MIL-STD-883
Microcircuits

QQ-N-288
Nickel-Copper Alloy & Nickel-Copper-Silicon Alloy Castings

Document Number

ASTM-E1105-15R23

Revision Level

2015 R23 EDITION

Status

Current

Publication Date

Feb. 6, 2023

Document Type

Test Method

Page Count

6 pages

Committee Number

E06.51