ASTM-E1198 Standard Practice for Sampling Zooplankton with Pumps

ASTM-E1198 - 2024 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Sampling Zooplankton with Pumps
ORDER

Price:

$55.00        


Want this as a site license?

Scope

1.1 This practice covers the procedures for obtaining qualitative/quantitative samples of a zooplankton community by use of pumping systems.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 The advantages of collecting zooplankton with pumps are as follows:

5.1.1 Sample size is more accurately controlled than with nets.

5.1.2 Discrete samples can be more easily obtained both vertically and horizontally.

5.1.3 Multiple or replicate samples can be more easily obtained.

5.1.4 The pumps are adaptable to a variety of ecosystems less than 30 m deep.

5.1.5 Sampling efficiency does not decrease with sample size.

5.2 The disadvantages of collecting zooplankton with pumps are as follows:

5.2.1 Pumps are bulky and require an electrical source.

5.2.2 Pumps are generally more costly than nets.

5.2.3 Pumps generally discriminate against collecting macroplankton.

5.2.4 Pump intake tubes may be avoided by the more motile zooplankton forms.

5.2.5 Requires a long, bulky, intake tube for deep water sampling.

5.3 There are several special considerations that should be observed when collecting zooplankton with a pump. They are:

5.3.1 Some pumps can fragment zooplankton and induce mortality due to their design.

5.3.2 The pump hose must be cleared before taking the next sample.

Keywords

zooplankton;

To find similar documents by ASTM Volume:

11.02 (Water (II))

11.05 (Pesticides and Alternative Control Agents; Environmental Assessment; Hazardous Substances and Oil Spill Response)

11.06 (Biological Effects and Environmental Fate; Biotechnology)

To find similar documents by classification:

13.060.30 (Sewage water Including sewage water disposal and treatment Liquid wastes, see 13.030.20 Drainage systems, see 91.140.80 Sewage systems, see 93.030)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1198-24

Revision Level

2024 EDITION

Status

Current

Modification Type

Revision

Publication Date

April 10, 2024

Document Type

Practice

Page Count

2 pages

Committee Number

D19.24