ASTM-E1631 Standard Practice for Use of Calorimetric Dosimetry Systems for Electron Beam Dose Measurements and Dosimeter Calibrations (Withdrawn 2002)

ASTM-E1631 - 1996(E1) EDITION - CANCELLED -- See the following: ASTM-51631
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Use of Calorimetric Dosimetry Systems for Electron Beam Dose Measurements and Dosimeter Calibrations (Withdrawn 2002)

Scope

1.1 This practice covers the preparation and use of semi-adiabatic calorimeters for measurement of absorbed dose in graphite, water, or polystyrene when irradiated with electrons. The calorimeters are either transported by a conveyor past a scanned electron beam or are stationary in a broadened beam. It also covers the use of these calorimeters to calibrate dosimeter systems in electron beams intended for radiation processing applications.

1.2 This practice applies to electron beams in the energy range from 4 to 12 MeV.

1.3 The absorbed dose range depends on the absorbing material and the irradiation and measurement conditions. Minimum dose is approximately 100 Gy and maximum dose is approximately 50 kGy.

1.4 The averaged absorbed dose rate range shall generally be greater than 10 Gy[dot]s -1 , but depends on the same conditions as above.

1.5 The temperature range for use of these calorimeters depends on the thermal resistance of the materials and on the calibration range of the temperature sensor.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

Absorbed radiation dose; Calibration-nuclear analysis instrumentation; Calorimeter; Dosimetry; Electron beam; Graphite; Ionizing radiation; Irradiance/irradiation; Polystyrene (PS); Radiation exposure-nuclear materials/applications; Threshold detectors-4 to 12 MeV; Water; ICS Number Code 17.240 (Radiation measurements)

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

This document comes with our free Notification Service, good for the life of the document.

This document is available in Paper format.

Document Number

ASTM-E1631-96e1

Revision Level

1996(E1) EDITION

Status

Cancelled

Modification Type

Replaced

Publication Date

June 1, 1999

Document Type

Practice

Page Count

9 pages

Committee Number

E10.01