Scope

1.1 This practice covers procedures for measuring and compensating for reflected temperature when measuring the surface temperature of a specimen with an infrared imaging radiometer.2

1.2 These procedures may involve use of equipment and materials in the presence of heated or electrically energized equipment, or both.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

5.1 The infrared energy that is reflected by a specimen can cause measurement errors for an infrared thermographer measuring its surface temperature. Two procedures are provided for measuring and compensating for this reflected temperature error source, the Reflector Method and the Direct Method.

5.2 These procedures can be used in the field or laboratory using commonly available materials.

5.3 These procedures can be used with any infrared radiometers that have the required computer capabilities.

5.4 Due to the nature of the specimens, the repeatability and reproducibility are subjective. However, a measure of the precision of the procedures can be inferred from the results of the replicate procedures specified in 8.1.6 and 8.2.7.

Keywords

imaging; infrared; infrared examination; infrared reflector; infrared testing; infrared thermography; nondestructive testing; radiometry; reflected temperature; temperature compensation; temperature measurement ;

To find similar documents by ASTM Volume:

03.03 (Nondestructive Testing)

To find similar documents by classification:

17.200.10 (Heat. Calorimetry)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E1862-14(2018)

Revision Level

2014 R18 EDITION

Status

Superseded

Modification Type

Reapproval

Publication Date

Dec. 1, 2018

Document Type

Practice

Page Count

3 pages

Committee Number

E07.10