ASTM-E481 Historical Revision Information
Standard Test Method for Measuring Neutron Fluence Rates by Radioactivation of Cobalt and Silver

ASTM-E481 - 1986 EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Test Method for Measuring Neutron Fluence Rates by Radioactivation of Cobalt and Silver
ORDER

Scope

1.1 This test method covers a suitable means of obtaining the thermal neutron fluence rate, or fluence, in well moderated nuclear reactor environments where the use of cadmium, as a thermal neutron shield as described in Method E262, is undesirable because of potential spectrum perturbations or of temperatures above the melting point of cadmium.

1.2 This test method describes a means of measuring a Westcott neutron fluence rate (Note 1) by activation of cobalt- and silver-foil monitors (see Terminology E170). The reaction 59 Co(n,[gamma]) 60 Co results in a well-defined gamma emitter having a half-life of 5.271 years (1). The reaction 109 Ag(n, [gamma] ) 110m Ag results in a nuclide with a complex decay scheme which is well known and having a half-life of 249.85 days (1). Both cobalt and silver are available either in very pure form or alloyed with other metals such as aluminum. A reference source of cobalt in aluminum alloy to serve as a neutron fluence rate monitor wire standard is available from the National Bureau of Standards as Standard Reference Material 953. The competing activities from neutron activation of other isotopes are eliminated, for the most part, by waiting for the short-lived products to die out before counting. With suitable techniques, thermal neutron fluence rate in the range from 10 cm -2 [dot]s -1 to 3 X 10 15 cm -2 [dot]s -1 can be measured. For this method to be applicable, the reactor must be well moderated and be well represented by a Maxwellian low-energy distribution and an (1/E) epithermal distribution. These conditions are usually met in positions surrounded by hydrogenous moderator without nearby strongly absorbing materials. Otherwise the true spectrum must be calculated to obtain effective activation cross sections over all energies.

Note 1-Westcott fluence rate = v0[integral] [infinity] 0 n(v)dv .

1.3 The values stated in SI units are to be regarded as the standard.

1.4 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Keywords

activation; cobalt; dosimetry; foil; silver; thermal neutron; ICS Number Code 17.240 (Radiation measurements); 27.120.30 (Fissile materials and nuclear fuel technology)

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

27.120.30 (Fissile materials and nuclear fuel technology Including raw materials Radioactive wastes, see 13.030.30)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-E481-86

Revision Level

1986 EDITION

Status

Superseded

Modification Type

Revision

Publication Date

Oct. 31, 1986

Document Type

Test Method

Page Count

8 pages

Committee Number

E10.05