ASTM-F720 Standard Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test

ASTM-F720 - 2017 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Testing Guinea Pigs for Contact Allergens: Guinea Pig Maximization Test
ORDER

Price:

$55.00        


Want this as a site license?

Changes from the previous issue

A redline edition is available for this document, with all changes visible. Ask Document Center Inc. for more information.

Scope

1.1 This practice is intended to determine the potential for a substance, or material extract, to elicit contact dermal allergenicity.

1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health and environmental practices and determine the applicability of regulatory limitations prior to use.

1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Significance and Use

4.1 In selecting a new material for human contact in medical applications, it is important to ensure that the material will not stimulate the immune system to produce an allergic reaction. The reaction would be due to substances which could leach out of a material. Therefore, this practice provides for using material extracts. The rationale for this practice is based on the fact that the guinea pig has been shown to be the best animal model for human allergic contact dermatitis. The use of Freund’s complete adjuvant and sodium lauryl sulfate tends to enhance the potential of a material to cause an allergy. Therefore, this test, while not guaranteeing that a material is nonallergenic, is the most severe animal test in common use today.

Keywords

acute toxicity tests; allergenicity; biocompatibility; guinea pigs; sensitization; test animals;; ICS Number Code 11.220 (Veterinary medicine)

To find similar documents by ASTM Volume:

13.01 (Medical and Surgical Materials and Devices)

To find similar documents by classification:

11.220 (Veterinary medicine Including equipment specific to veterinary medicine)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IPC-A-610
Acceptability of Electronic Assemblies (Hardcopy format)

MIL-STD-883
Microcircuits

ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems

Document Number

ASTM-F720-17

Revision Level

2017 EDITION

Status

Current

Modification Type

Revision

Publication Date

Sept. 15, 2017

Document Type

Practice

Page Count

3 pages

Committee Number

F04.16