Scope

1.1 This practice describes the determination of the relative actinic effects of individual spectral bands of an exposure source on a material. The activation spectrum is specific to the light source to which the material is exposed to obtain the activation spectrum. A light source with a different spectral power distribution will produce a different activation spectrum.

1.2 This practice describes two procedures for determining an activation spectrum. One uses sharp cut-on UV/visible transmitting filters and the other uses a spectrograph to determine the relative degradation caused by individual spectral regions.

Note 1-Other techniques can be used to isolate the effects of individual spectral bands of a light source, for example, interference filters.

1.3 The techniques are applicable to determination of the spectral effects of solar radiation and laboratory accelerated test devices on a material. They are described for the UV region, but can be extended into the visible region using different cut-on filters and appropriate spectrographs.

1.4 The techniques are applicable to a variety of materials, both transparent and opaque, including plastics, paints, inks, textiles and others.

1.5 The optical and/or physical property changes in a material can be determined by various appropriate methods. The methods of evaluation are beyond the scope of this practice.

1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Note 2-There is no ISO standard that is equivalent to this standard.

Keywords

activation spectrum; cumulative spectral sensitivity curve; degradation; light exposure; sharp cut-on filter technique; spectrographic technique; ultraviolet radiation; ICS Number Code 71.040.50 (Physicochemical methods of analysis)

To find similar documents by ASTM Volume:

14.04 (Laboratory Apparatus; Degradation of Materials; SI; Oxygen Fire Safety)

To find similar documents by classification:

71.040.50 (Physicochemical methods of analysis Including spectrophotometric and chromatographic analysis)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ASTM-G0178-16R23

Revision Level

2016 R23 EDITION

Status

Current

Modification Type

New

Publication Date

Feb. 20, 2023

Document Type

Practice

Page Count

13 pages

Committee Number

G03.01