IEC-60332-3-23 Historical Revision Information
Part 3-23: Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables -

IEC-60332-3-23 - 1ST EDITION - SUPERSEDED
Show Complete Document History

Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:


IEC 60332-3-23:2000+A1:2008 specifies method of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions. The test is intended for type approval testing. The requirements for the selection of cables for testing are given. The flame spread is measured as the extent of damage of the cable sample. This procedure may be used to demonstrate the cable's ability to limit flame spread. Covers category B and relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 3,5 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where medium volumes of non-metallic material are required to be evaluated. A recommended performance requirement is also given. Has the status of a group safety publication in accordance with IEC Guide 104. This consolidated version consists of the first edition (2000) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.
ORDER

Document Number

IEC 60332-3-23 Ed. 1.0 b:2000

Revision Level

1ST EDITION

Status

Superseded

Publication Date

Oct. 1, 2000

Committee Number

20