IEC-61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements

IEC-61010-1 - EDITION 3.1 - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:


IEC 61010-1:2010+A1:2016 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.
a) Electrical test and measurement equipment
b) Electrical industrial process-control equipment c) Electrical laboratory equipment
This third edition cancels and replaces the second edition published in 2001. It constitutes a technical revision. This edition includes the following significant changes from the second edition, as well as numerous other changes.
- The scope of the standard has been expanded to include all locations where these products may be used, so that both professional and non-professional versions of these products are within the scope.
- The requirements for testing and measuring circuits (in various subclauses and the entirety of Clause 16) have been removed and included in a particular standard IEC 61010-2-030.
- Insulation requirements (6.7) have been completely rewritten.
- Additional requirements for protection against mechanical HAZARDS (Clause 7) have been included.
- Surface temperature limits (Clause 10) have been modified to conform to the limits of EN 563.
- Radiation requirements (Clause 12) have been modified, and take into account a distinction between intended emission and unintended emission.
- Requirements for reasonably foreseeable misuse and ergonomic aspects have been added (Clause 16).
- A new clause (Clause 17) has been added to deal with HAZARDS and environments not covered by the standard, along with a new informative annex (Annex J) dealing with RISK assessment.
- A new informative annex (Annex E) addresses methods of reducing the POLLUTION DEGREE of a micro-environment.
- Requirements for the qualification of coatings for protection against POLLUTION have been added (Annex H).
- A new informative annex (Annex I) has been added to further explain how to determine the WORKING VOLTAGE of a MAINS CIRCUIT.
It has the status of a horizontal standard in accordance with IEC Guide 104. The contents of the corrigendum 1 of May 2011, the interpretation sheet 1 of February 2013 and the corrigendum 2 of October 2013 have been included in this copy.
This consolidated version consists of the third edition (2010) and its amendment 1 (2016). Therefore, no need to order amendment in addition to this publication.
ORDER

Price:

$999.10        


Want this as a site license?

Abstract

IEC 61010-1:2010 specifies general safety requirements for the following types of electrical equipment and their accessories, wherever they are intended to be used.
a) Electrical test and measurement equipment
b) Electrical industrial process-control equipment
c) Electrical laboratory equipment

This third edition cancels and replaces the second edition published in 2001. It constitutes a technical revision. This edition includes the following significant changes from the second edition, as well as numerous other changes.
- The scope of the standard has been expanded to include all locations where these products may be used, so that both professional and non-professional versions of these products are within the scope.
- The requirements for testing and measuring circuits (in various subclauses and the entirety of Clause 16) have been removed and included in a particular standard IEC 61010-2-030.
- Insulation requirements (6.7) have been completely rewritten.
- Additional requirements for protection against mechanical HAZARDS (Clause 7) have been included.
- Surface temperature limits (Clause 10) have been modified to conform to the limits of EN 563.
- Radiation requirements (Clause 12) have been modified, and take into account a distinction between intended emission and unintended emission.
- Requirements for reasonably foreseeable misuse and ergonomic aspects have been added (Clause 16).
- A new clause (Clause 17) has been added to deal with HAZARDS and environments not covered by the standard, along with a new informative annex (Annex J) dealing with RISK assessment.
- A new informative annex (Annex E) addresses methods of reducing the POLLUTION DEGREE of a micro-environment.
- Requirements for the qualification of coatings for protection against POLLUTION have been added (Annex H).
- A new informative annex (Annex I) has been added to further explain how to determine the WORKING VOLTAGE of a MAINS CIRCUIT.

It has the status of a group safety publication, as specified in IEC Guide 104. The contents of the corrigendum of May 2011 have been included in this copy.

To find similar documents by classification:

19.080 (Electrical and electronic testing Including testing equipment Equipment for measuring electrical and magnetic quantities, see 17.220.20)

71.040.10 (Chemical laboratories. Laboratory equipment Including hydrometers, alcoholometers, etc. Apparatus for measurement of volume, mass, density, viscosity, see 17.060 Spectroscopes, see 17.180.30 Temperature-measuring instruments, see 17.200.20 Laboratory ware, see 71.040.20)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IPC-A-610
Acceptability of Electronic Assemblies (Hardcopy format)

ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems

IEC-60601-1
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance

Document Number

IEC 61010-1 Ed. 3.1 b:2017

Revision Level

EDITION 3.1

Status

Current

Publication Date

Jan. 1, 2017

Committee Number

66