IEC-61223-3-2 Evaluation and routine testing in medical imaging departments - Part 3-2: Acceptance tests - Imaging performance of mammographic X-ray equipment

IEC-61223-3-2 - 2ND EDITION - CURRENT


Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This part of IEC 61223 applies to the effectiveness of mammographic X-ray equipment, with respect to image quality and dose, in combination with aspects of equipment safety. This standard applies to mammographic X-ray equipment and mammographic stereotactic devices. The tests described in this standard require the quality and performance of the X-ray image receptors to be assured prior to the acceptance testing when they are not an integral part of the mammographic X-ray equipment. This includes radiographic films, intensifying screens, radiographic cassettes, storage phosphor plates and associated equipment such as film processors or storage phosphor plate readers, image display devices and hard copy cameras. For testing radiographic cassettes and intensifying screens, this standard makes reference to ISO 4090. Sensitivity and contrast for the screen-film image receptors are considered to be stated according to ISO 9236-3. By the measurements described in this standard, data for average glandular dose calculation can be determined. When the results of the acceptance test are in compliance with the expected values, the baseline values for the subsequent constancy tests are established. This part of IEC 61223 defines a) the essential parameters which describe the performance of the above-mentioned mammographic X ray equipment with regard to image quality and dose; and b) the methods of testing whether measured quantities related to those parameters comply with specified tolerances. These methods mainly rely on non-invasive measurements that use appropriate test equipment and are performed during or after the installation. Signed statements covering steps in the installation procedure can be used as part of the acceptance test. Tests required by a higher level of compliance take precedence over similar tests with a lower level of compliance.
ORDER

Price:

$430.68        


Want this as a site license?

To find similar documents by classification:

11.040.50 (Radiographic equipment Including radiographic diagnostic and therapy equipment Dental, medical and industrial radiographic films, see 37.040.25)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IEC-61223-2-6
Evaluation and routine testing in medical imaging departments ­ Part 2­6: Constancy tests ­ Imaging performance of computed tomography X-ray equipment

IEC-1223-2-4
Part 2-4: Constancy Tests - Hard Copy Cameras, Evaluation &Routine Testing in Medical IMA

IEC-1223-2-5
Part 2-5: Constancy Tests - Image Display Devices, Evaluation & Routine Testing in Medical

Document Number

IEC 61223-3-2 Ed. 2.0 b:2007

Revision Level

2ND EDITION

Status

Current

Publication Date

July 1, 2007

Committee Number

62B