IEC-918 › PVC insulated ribbon cable with a pitch of 1.27 mm suitable for insulation displacement termination
IEC-918
-
1ST EDITION
-
CURRENT
Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:
The following bibliographic material is provided to assist you with your purchasing decision:
Applicable to PVC insulated ribbon cables with a pitch of 1.27 mm and with a maximum of 64 conductors suitable for the insulation displacement (ID) method of termination. Specifies requirements and dimensions for flexible, flat, unscreened cables, with either solid or stranded conductors. The cables are suitable for operation in equipment at voltages up to and including 300 V r.m.s. to earth, or between cores, and at conductor temperatures from -10¦C to 90¦C.
To find similar documents by classification:
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
IEC 60918 Ed. 1.0 b:1987
Revision Level
1ST EDITION
Status
Current
Publication Date
Jan. 1, 1987
Committee Number
46C