IEC/IEEE-62271-37-013 High-voltage switchgear and controlgear - Part 37-013: Alternating current generator circuit-breakers

IEC/IEEE-62271-37-013 - EDITION 2.0 - CURRENT


Document Center Inc. is an authorized dealer of IEC standards.
The following bibliographic material is provided to assist you with your purchasing decision:


IEC/IEEE 62271-37-013:2021 is applicable to three-phase AC high-voltage generator circuit-breakers, hereafter called generator circuit-breakers, designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 kV and up to 38 kV.
This document is published as an IEC/IEEE Dual Logo standard.
The IEEE Std C37.013.-1997 (R2008) was revised and converted into the first edition of the IEC/IEEE Dual Logo International Standard IEC/IEEE 62271-37-013 published in 2015.
This second edition cancels and replaces the first edition published in 2015. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
  1. content has been added to address the requirements of the other components of the generator circuit breaker system;
  2. requirements for the application of generator circuit-breakers in power plants with multiple generators connected to one step-up transformer have been added;
  3. requirements for testing and application of Tee-OFF generator circuit-breakers have been added;
  4. requirements for application of generator circuit-breakers in power plants with doubly-fed induction machines, pumped-storage power plants, and wind farms have been added;
  5. the clause numbering has been aligned with the numbering in IEC 62271-1:2017;
  6. the topic of reference mechanical characteristics has been revised to improve clarity;
  7. the modifying effects of capacitors on the prospective TRVs for out-of-phase and load current switching has been addressed in Annex M and in Annex N with use of the tool named "GenCB TRV calculator". This tool provides the values of KE2, RRRV0, KRRRV-U, KRRRV-I, td0, Ktd-U, Ktd-I, as well as the values of the parameters of the prospective TRV modified by the capacitors of the generator circuit-breaker.
This document contains attached files in the form of Excel spreadsheets ("GenCB TRV calculator"). These files are intended to be used as a complement and do not form an integral part of the document.
ORDER

Price:

$530.59        

To find similar documents by classification:

29.130.10 (High voltage switchgear and controlgear Including enclosed switchgear and controlgear)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

IEC/IEEE 62271-37-013 Ed. 2.0 en:2021

Revision Level

EDITION 2.0

Status

Current

Publication Date

Oct. 1, 2021

Committee Number

17A