ISO-23500-2 Preparation and quality management of fluids for haemodialysis and related therapies - Part 2: Water treatment equipment for haemodialysis applications and related therapies

ISO-23500-2 - 1ST EDITION - CURRENT


Document Center Inc. is an authorized dealer of ISO standards.
The following bibliographic material is provided to assist you with your purchasing decision:


1.1 General

This document is addressed to the manufacturer and/or supplier of water treatment systems and/or devices used for the express purpose of providing water for haemodialysis or related therapies.

1.2 Inclusions

This document covers devices used to treat potable water intended for use in the delivery of haemodialysis and related therapies, including water used for:

a) the preparation of concentrates from powder or other highly concentrated media at a dialysis facility;

b) the preparation of dialysis fluid, including dialysis fluid that can be used for the preparation of substitution fluid;

c) the reprocessing of dialysers intended for single use where permitted for multiple uses,

d) the reprocessing of dialysers not specifically marked as intended for single use.

This document includes all devices, piping and fittings between the point at which potable water is delivered to the water treatment system, and the point of use of the dialysis water. Examples of the devices are water purification devices, online water quality monitors (such as conductivity monitors), and piping systems for the distribution of dialysis water.

1.3 Exclusions

This document excludes dialysis fluid supply systems that proportion water and concentrates to produce dialysis fluid, sorbent dialysis fluid regeneration systems that regenerate and recirculate small volumes of the dialysis fluid, dialysis concentrates, haemodiafiltration systems, haemofiltration systems, systems that process dialysers for multiple uses, and peritoneal dialysis systems. Some of these devices, such as dialysis fluid delivery systems and concentrates, are addressed in other documents such as ISO 23500-4 and ISO 23500‑5,

This document also excludes the on-going surveillance of the purity of water used for dialysis fluid, concentrate preparation, or dialyser reprocessing which is addressed in ISO 23500‑1.

ORDER

Price:

$188.18        


Want this as a site license?

To find similar documents by classification:

11.040.40 (Implants for surgery, prosthetics and orthotics Including pacemakers Ophthalmic implants, see 11.040.70)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

Document Number

ISO 23500-2:2019

Revision Level

1ST EDITION

Status

Current

Publication Date

Feb. 1, 2019

Committee Number

ISO/TC 150/SC 2