ISO-8467 › Water quality - Determination of permanganate index
The following bibliographic material is provided to assist you with your purchasing decision:
The principle of the method specified is heating a sample in a boiling water-bath with a known amount of potassium permanganate und sulfuric acid for a fixed period time (10 min), reducing part of the permanganate by oxidizable material in the sample and determining the consumed permanganate by addition of an excess of oxalate solution, followed by titration with permanganate. Applies to waters having a cloride ion concentration of less than 300 mg/l. Samples having a permanganate index over 10 mg/l should be diluted before analysis. The lower limit of the optimum range of the test is 0,5 mg/l.
To find similar documents by classification:
13.060.50 (Examination of water for chemical substances)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Document Number
ISO 8467:1993
Revision Level
2ND EDITION
Status
Current
Publication Date
June 15, 1993
Committee Number
ISO TC 147/SC 2