This Technical Specification describes a standard method for determining the particle number concentration in ambient air in a range up to about 107 cm–3 for averaging times equal to or larger than 1 min. The standard method is based on a Condensation Particle Counter (CPC) operated in the counting mode and an appropriate dilution system for concentrations exceeding the counting mode range. It also defines the performance characteristics and the minimum requirements of the instruments to be used. The lower and upper sizes considered within this document are 7 nm and a few micrometres, respectively. This document describes sampling, operation, data processing and QA/QC procedures including calibration parameters.
To find similar documents by classification:
13.040.20 (Ambient atmospheres Including indoor air)
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Designation Name
SIS-CEN/TS 16976:2019
Revision Level
2019 EDITION
Status
Current
Publication Date
Jan. 8, 2019
Language(s)
English
Page Count
68