SS-EN-ISO-11608-1 Needle-based injection systems for medical use - Requirements and test methods - Part 1: Needle-based injection systems (ISO 11608-1:2022)

SS-EN-ISO-11608-1 - 2022 EDITION - CURRENT
Show Complete Document History

Document Center Inc. is an authorized dealer of SIS standards.
The following bibliographic material is provided to assist you with your purchasing decision:


This document specifies requirements and test methods for Needle-Based Injection Systems (NISs) for single-patient use intended to deliver discrete volumes (bolus) of medicinal product, which can be delivered through needles or soft cannulas for intradermal, subcutaneous and/or intramuscular delivery, incorporating pre-filled or user-filled, replaceable or non-replaceable containers. This document applies in cases where the NIS incorporates a prefilled syringe. However, stand-alone prefilled syringes defined by ISO 11040-8 are not covered by this document (see exclusions below). It is important to note that other functions and characteristics of the prefilled syringe, such as dose accuracy, are subject to the requirements (delivered volume) in ISO 11040-8 and not this document, unless the addition impacts the delivery function (e.g. a mechanism that intends to restrict or stop the plunger movement, which would limit the dose delivered). In that case, the system is completely covered by this document and applicable requirements of the ISO 11608 series. Excluded from the scope are: —    stand-alone prefilled syringes defined by ISO 11040-8 (with noted exceptions above); —    NISs that provide continuous delivery and require a delivery rate clinically specified in the medicinal product labelling or determined by a physician based on clinical relevance (i.e. medication efficacy) as would be the case with insulin patch pumps or traditional infusion pumps (e.g. IEC 60601-2-24, ISO 28620) associated with continuous delivery of medicinal products (e.g. insulin); —    NISs with containers that can be refilled multiple times; —    requirements relating to methods or equipment associated with user filling of containers unless they are dedicated accessories (a component necessary for primary function, whether included in the original kitted product or not); —    NISs intended for dental use; —    NISs intended for different routes of administration (e.g. intravenous...

To find similar documents by classification:

11.040.20 (Transfusion, infusion and injection equipment Including blood packs Syringes, needles and catheters, see 11.040.25)

11.040.25 (Syringes, needles and catheters)


Medical devices

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

IEC-60529
Degrees of protection provided by enclosures (IP Code)

SIS-EN-ISO-13485
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)

ASTM-F1980
Standard Guide for Accelerated Aging of Sterile Barrier Systems and Medical Devices

ORDER

Price:

$219.75        


Want this as a site license?



Designation Name

SS-EN ISO 11608-1:2022

Revision Level

2022 EDITION

Status

Current

Publication Date

May 9, 2022

Language(s)

English

Page Count

84

International Equivalent

EN ISO 11608-1:2022(IDT); ISO 11608-1:2022(IDT)