pe 1.1 Inclusions 1.1.1 This part of ISO 17665 specifies requirements for the development, validation and routine control of a moist heat sterilization process for medical devices. NOTE Although the scope of this part of ISO 17665 is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other health care products. 1.1.2 Moist heat sterilization processes covered by this part of ISO 17665 include but are not limited to: a) saturated steam venting systems; b) saturated steam active air removal systems; c) air steam mixtures; d) water spray; e) water immersion. NOTE See also Annex E. 1.2 Exclusions 1.2.1 This part of ISO 17665 does not specify requirements for development, validation, and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease. Specific recommendations have been produced in particular countries for the processing of materials potentially contaminated with these agents. NOTE See also ISO 22442-1, ISO 22442-2 and ISO 22442-3. 1.2.2 This part of ISO 17665 does not apply to those sterilization processes that are based on a combination of moist heat with other biocidal agents (e.g. formaldehyde) as the sterilizing agent. 1.2.3 This part of ISO 17665 does not detail a specified requirement for designating a medical device as sterile. NOTE Attention is drawn to national or regional requirements for designating medical devices as sterile. See, for example, EN 556-1 or ANSI/AAMI ST67.
To find similar documents by classification:
Active implantable medical devices. Medical devices. In vitro diagnostic medical devices
This document comes with our free Notification Service, good for the life of the document.
This document is available in either Paper or PDF format.
Customers who bought this document also bought:
UL-94Standard for Tests for Flammability of Plastic Materials for Parts in Devices and Appliances
ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems
ASTM-F88
Standard Test Method for Seal Strength of Flexible Barrier Materials
Designation Name
SS-EN ISO 17665-1:2006
Revision Level
2006 EDITION
Status
Current
Publication Date
Aug. 17, 2006
Language(s)
English
Page Count
46
International Equivalent
EN ISO 17665-1:2006(IDT); ISO 17665-1:2006(IDT)