ASTM-51204 Standard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)

ASTM-51204 - 2004 EDITION - SUPERSEDED -- See the following: ASTM-51702
Show Complete Document History

Document Center Inc. is an authorized dealer of ASTM standards.
The following bibliographic material is provided to assist you with your purchasing decision:

Standard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)

Scope

1.1 This practice outlines the installation qualification program for an irradiator and the dosimetric procedures to be followed during operational qualification, performance qualification, and routine processing in facilities that process food with ionizing radiation from radionuclide gamma sources to ensure that product has been treated within a predetermined range of absorbed dose. Other procedures related to operational qualification, performance qualification, and routine processing that may influence absorbed dose in the product are also discussed. Information about effective or regulatory dose limits for food products is not within the scope of this practice (see ASTM Guides F 1355, F 1356, F 1736, and F 1885).

Note 1—Dosimetry is only one component of a total quality assurance program for adherence to good manufacturing practices used in the production of safe and wholesome food.

Note 2—ISO/ASTM Practice 51431 describes dosimetric procedures for electron beam and X-ray (bremsstrahlung) irradiation facilities for food processing.

1.2 For guidance in the selection and calibration of dosimetry systems, and interpretation of measured absorbed dose in the product, see ISO/ASTM Guide 51261 and ASTM Practice E 666. For the use of specific dosimetry systems, see ASTM Practices E 1026 and E 2304, and ISO/ASTM Practices 51205, 51275, 51276, 51310, 51401, 51538, 51540, 51607, 51650, and 51956. For discussion of radiation dosimetry for gamma-rays and X-rays also see ICRU Report 14.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Significance and Use

4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic microorganisms, insect disinfestation, growth and maturation inhibition, and shelf-life extension. Food irradiation specifications almost always include a minimum or maximum limit of absorbed dose, sometimes both: a minimum limit is set to ensure that the intended beneficial effect is achieved and a maximum limit is set for the purpose of avoiding product or packaging degradation. For a given application, one or both of these values may be prescribed by government regulations that have been established on the basis of scientific data. Therefore, prior to the irradiation of the food product, it is necessary to determine the capability of an irradiation facility to deliver the absorbed dose within any prescribed limits. Also, it is necessary to monitor and document the absorbed dose during each production run to verify compliance with the process specifications at a predetermined level of confidence.

NOTE 3 - The Codex Alimentarius Commission has developed an international General Standard and a Code of Practice that address the application of ionizing radiation to the treatment of foods and that strongly emphasize the role of dosimetry for ensuring that irradiation will be properly performed (1).

4.2 Some food products are processed in the chilled or frozen state. Therefore, dosimeters used for routine processing should be selected for their functionality under those conditions. Moreover, the temperature of a dosimeter during irradiation should be sufficiently stable to allow correction for temperature effects on the dosimeter response. To avoid the influence of temperature gradients on dosimeter response and the subsequent need to correct for these effects, methods that isolate the dosimeter from temperature gradients may be employed.

NOTE 4 - For more detailed discussions of radiation processing of various foods, see ASTM Guides F 1355, F 1356, F 1736, and F 1885 and Refs (1-11).

4.3 To ensure that products are irradiated within a specified absorbed-dose range, routine process control requires routine product dosimetry, documented product handling procedures (before, during, and after irradiation), consistent orientation of the products during irradiation, monitoring of critical process parameters, and documentation of all relevant activities and functions.

Keywords

absorbed dose; cobalt-60; cesium-137; dose mapping; dosimeter; dosimetry; food irradiation; food processing; gamma; installation qualification; ionizing radiation; irradiated food; irradiation; operational qualification; performance qualification; radiation; ICS 17.240; ICS

To find similar documents by ASTM Volume:

12.02 (Nuclear (II), Solar, and Geothermal Energy)

To find similar documents by classification:

17.240 (Radiation measurements Including dosimetry Radiation protection, see 13.280)

67.020 (Processes in the food industry Including food hygiene and food safety)

This document comes with our free Notification Service, good for the life of the document.

This document is available in either Paper or PDF format.

 

Customers who bought this document also bought:

ASTM-D4169
Standard Practice for Performance Testing of Shipping Containers and Systems

ASTM-A269
Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service

ASTM-A313
Standard Specification for Stainless Steel Spring Wire

Document Number

ISO/ASTM51204-04

Revision Level

2004 EDITION

Status

Superseded

Modification Type

Replaced

Publication Date

Jan. 1, 2004

Document Type

ISO/ASTM

Page Count

10 pages

Committee Number

E61.05